Installing and activating RSLogix 5
Rockwell Automation Publication - LG5-GR002E-EN-P - December 2019 37
This action: If granted to a user:
Prompt for audit comment on extended force data
clearing
If auditing is enabled*, the user will be prompted for a
comment when clearing external force files.
Prompt for audit comment on extended force data
configuration
If auditing is enabled*, the user will be prompted for a
comment when configuring external forces.
Prompt for audit comment on Going Offline If auditing is enabled*, the user will be prompted for a
comment when going offline.
Prompt for audit comment on Going Online If auditing is enabled*, the user will be prompted for a
comment when going online with a controller.
Prompt for audit comment on I/O auto configuration If auditing is enabled*, the user will be prompted for a
comment when autoconfiguring I/O.
Prompt for audit comment on Inserting a Replacement
Rung
If auditing is enabled*, the user will be prompted for a
comment when inserting a replacement ladder logic
rung.
Prompt for audit comment on Inserting a Rung If auditing is enabled*, the user will be prompted for a
comment when inserting a rung into a ladder logic
program.
Prompt for audit comment on Inserting Data File If auditing is enabled*, the user will be prompted for a
comment when creating a data table file.
Prompt for audit comment on Inserting Program File If auditing is enabled*, the user will be prompted for a
comment when creating a program file.
Prompt for audit comment on Loading from EEPROM If auditing is enabled*, the user will be prompted for a
comment when loading a program from EEPROM.
Prompt for audit comment on Marking Rung for Deletion If auditing is enabled*, the user will be prompted for a
comment when marking a rung for deletion.
Prompt for audit comment on Online Ladder Edits If auditing is enabled*, the user will be prompted for a
comment when editing ladder logic while online.
Prompt for audit comment on Partial Downloading
program from Processor
If auditing is enabled*, the user will be prompted for a
comment when using the partial download feature.
Prompt for audit comment on Partial Uploading program
from Processor
If auditing is enabled*, the user will be prompted for a
comment when using the partial upload feature.
Prompt for audit comment on processor name change If auditing is enabled*, the user will be prompted for a
comment when changing the name of a controller.
Prompt for audit comment on program file name change If auditing is enabled*, the user will be prompted for a
comment when changing the name of a program file.
Prompt for audit comment on reset of diagnostic counters If auditing is enabled*, the user will be prompted for a
comment when resetting diagnostic counters.
Prompt for audit comment on Rung Deletion If auditing is enabled*, the user will be prompted for a
comment when deleting a ladder logic rung.
Prompt for audit comment on scanlist modified If auditing is enabled*, the user will be prompted for a
comment when modifying a scanlist.
Prompt for audit comment on Storing to EEPROM If auditing is enabled*, the user will be prompted for a
comment when burning the EEPROM for a controller.
Prompt for audit comment on Testing Pending Edits If auditing is enabled*, the user will be prompted for a
comment when testing pending program edits.
Prompt for audit comment on Uploading program from
Processor
If auditing is enabled*, the user will be prompted for a
comment when uploading from a controller.
Replace The user may use the Replace function.
Save The user may save a project.