CISCO SYSTEMS PUBLICATION HISTORY
170 W
EST TASMAN DR
S
AN JOSE, CA, 95134 REV F.24 MAY 06, 2024
WWW.CISCO.COM
Spec Sheet
Cisco UCS C220 M5
Rack Server (Small Form
Factor Disk Drive Model)
This product has been discontinued
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
2
CONTENTS
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 7
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
STEP 2 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
STEP 3 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
STEP 4 SELECT RAID CONTROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
STEP 5 SELECT DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
STEP 6 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
STEP 7 ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . 38
STEP 8 ORDER GPU CARDS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
STEP 9 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
STEP 10 SELECT POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
STEP 11 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . 48
STEP 12 SELECT MANAGEMENT CONFIGURATION (OPTIONAL) . . . . . . . . . . . . . . . . . . . . 49
STEP 13 SELECT SERVER BOOT MODE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
STEP 14 ORDER SECURITY DEVICES (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
STEP 15 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . 52
STEP 16 ORDER CISCO SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . 53
STEP 17 ORDER M.2 SATA SSDs (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
STEP 18 ORDER INTERNAL MICRO-SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . 55
STEP 19 ORDER OPTIONAL USB 3.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
STEP 20 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 57
STEP 21 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
STEP 22 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
UPGRADING or REPLACING CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
UPGRADING or REPLACING MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
DISCONTINUED EOL PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
OVERVIEW
4
OVERVIEW
The UCS C220 M5 SFF server extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U
form factor with the 2
nd
Generation Intel
®
Xeon
®
Scalable Processors, DDR4-3200MHz memory, and the new
512GB Intel
®
Optane™ Persistent Memory Modules (PMem). With this combination of features, up to 9 TB of
memory is possible (using 12 x 256 GB DDR4 DIMMs and 12 x 512 GB PMem), two 2 PCI Express (PCIe) 3.0
slots, and up to 10 SAS/SATA hard disk drives (HDDs) or solid state drives (SSDs). The C220 M5 SFF server also
includes one dedicated internal slot for a 12G SAS storage controller card.
The C220 M5 server includes one dedicated internal modular LAN on motherboard (mLOM) connector for
installation of a Cisco Virtual Interface Card (VIC) or third-party network interface card (NIC), without
consuming a PCI slot, in addition to 2 x 10Gbase-T Intel x550 embedded (on the motherboard) LOM ports.
The Cisco UCS C220 M5 server can be used standalone, or as part of the Cisco Unified Computing System,
which unifies computing, networking, management, virtualization, and storage access into a single
integrated architecture, enabling end-to-end server visibility, management, and control in both bare metal
and virtualized environments.
Figure 1 Cisco UCS C220 M5 SFF Rack Server
Front View (without and with bezel
Rear View
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
5
DETAILED VIEWS
DETAILED VIEWS
Chassis Front View
Figure 2 shows the front view of the Cisco UCS C220 M5 SFF Rack Server.
Figure 2 Chassis Front View
1 Drive bays 1 – 10 support SAS/SATA hard
dri
ves and solid state drives (SSDs).
7 Fan status LED
2 UCSC-C220-M5SX version: Drive bays 1 and 2
s
upport SFF NVMe PCIe drives. But bays 1
and 2 can also be used for SFF SAS/SATA
HDDs and SSDs. Bays 3 - 10 support only
SAS/SATA HDDs and SDDs.
UCSC-C220-M5SN version: Drive bays 1 – 10
s
upport only SFF NVMe PCIe SSDs
8 Network link activity LED
3 Power button/Power status LED 9 Temperature status LED
4 Unit identification button/LED 10 Pull-out asset tag
5 System status LED 11 KVM connector (used with KVM cable that
provides
two USB 2.0, one VGA, and one
serial connector)
6 Power supply status LED - -
Slot 1 Slot 2
Slot 7
Slot 3
Slot 8
Slot 4
Slot 9
Slot 5
Slot 10
Slot 6
2 10
3
4
5
11
7
9
6
8
1
305949
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
6
Chassis Rear View
Figure 3 shows the external features of the rear panel.
Figure 3 Chassis Rear View
1 Modular LAN-on-motherboard (mLOM) card
bay (x16)
7 Rear unit identification button/LED
2 USB 3.0 ports (two) 8 Power supplies (two, redundant as 1+1)
3 Dual 1/10GE ports (LAN1 and LAN2)
LAN1 is left connector and
LAN2 is right connector
9 PCIe riser 2 (slot 2) (half-height, x16);
i
ncludes NVMe connectors for cabling to
connect to up to two front-mount SFF
NVMe SSDs (x8)
4 VGA video port (DB-15) 10 PCIe riser 1 (slot 1) (full-height, x16)
5 1GE Ethernet dedicated management
port 11 Threaded holes for dual-hole grounding
lug
6 Serial port (RJ-45 connector) - -
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
7
BASE SERVER STANDARD CAPABILITIES and FEATURES
BASE SERVER STANDARD CAPABILITIES and FEATURES
Ta b l e 1 lists the capabilities and features of the base server. Details about how to configure the server for
a particular feature or capability (for example, number of processors, disk drives, or amount of memory)
are provided in
CONFIGURING the SERVER, page 11.
Table 1 Capabilities and Features
Capability/Feature Description
Chassis One rack unit (1RU) chassis
CPU
One or two 2
nd
Generation Intel
®
Xeon
®
scalable family CPUs
Chipset
Intel
®
C621 series chipset
Memory 24 slots for registered DIMMs (RDIMMs), load-reduced DIMMs (LRDIMMs), or
through silicon via (TSV) DIMMs and support for Intel® Optane™ Persistent
Memory (PMem)
Multi-bit Error
Protection
This server supports multi-bit error protection.
Video The Cisco Integrated Management Controller (CIMC) provides video using the
Matrox G200e video/graphics controller:
Integrated 2D graphics core with hardware acceleration
512MB total DDR4 memory, with 16MB dedicated to Matrox video memory
Supports display resolutions up to 1920 x 1200 16bpp @ 60Hz
High-speed integrated 24-bit RAMDAC
Single lane PCI-Express host interface running at Gen 1 speed
SATA Interposer Board An optional SATA interposer board provides for up to eight SATA-only drives.
Power subsystem Up to two of the following hot-swappable power supplies:
770 W (AC)
1050 W (AC)
1050 W (DC)
1600 W (AC)
1050ELV (AC)
One power supply is mandatory; one more can be added for 1 + 1
redundancy.
Front Panel A front panel controller provides status indications and control buttons
ACPI This server supports the advanced configuration and power interface (ACPI)
6.2 standard.
Fans Seven hot-swappable fans for front-to-rear cooling
Infiniband The InfiniBand architecture is supported by the PCI slots.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES
8
Expansion slots Riser 1 (controlled by CPU 1):
One full-height profile, 3/4-length slot with x24 connector and x16
lane.
Riser 2 (controlled by CPU 2):
One half-height profile, half-length slot with x24 connector and x16
lane.
Dedicated RAID controller slot (see Figure 5 on page 67)
An internal slot is reserved for use by the Cisco 12G SAS RAID
controller or the Cisco 12G SAS HBA.
Interfaces Rear panel
One 1Gbase-T RJ-45 management port (Marvell 88E6176)
Two 10Gbase-T LOM ports (Intel X550 controller embedded on the
motherboard)
One RS-232 serial port (RJ45 connector)
One DB15 VGA connector
Two USB 3.0 port connectors
One flexible modular LAN on motherboard (mLOM) slot that can
accommodate various interface cards
Front panel
One KVM console connector (supplies two USB 2.0 connectors, one
VGA DB15 video connector, and one serial port (RS232) RJ45
connector)
Table 1 Capabilities and Features (continued)
Capability/Feature Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
9
BASE SERVER STANDARD CAPABILITIES and FEATURES
Internal storage devices Drive storage:
Drives are installed into front-panel drive bays that provide hot-swappable
access for SAS/SATA drives. The server is orderable in two different versions:
UCSC-C220-M5SX:
Up to 10 SFF SAS/SATA hard drives (HDDs) or SAS/SATA solid state
drives (SSDs).
Optionally, up to two SFF NVMe PCIe SSDs (replacing SAS/SATA
drives). These drives must be placed in front drive bays 1 and 2 only
and are connected to riser 2. The rest of the bays (3 - 10) can be
populated with SAS/SATA SSDs or HDDs. Two CPUs are required when
choosing NVMe SSDs.
UCSC-C220-M5SN:
Up to 10 SFF NVMe PCIe SSDs only. The drives in slots 1 and 2 are
connected to riser 2 and the drives in slots 3 through 10 are
connected to the PCIe switch card plugged into the internal HBA slot.
Two CPUs are required for the UCSC-C220-M5SN.
Other storage:
One internal USB 3.0 port on the motherboard that you can use with an
optional 16 GB USB thumb drive for additional storage.
A mini-storage module connector on the motherboard supports either:
An SD card module with two SD card slots. Mixing different capacity
SD cards is not supported.
• An M.2 module with two SATA M.2 SSD slots. Mixing different capacity
M.2 modules is not supported.
One socket for a micro-SD card on PCIe riser 1. The micro-SD card serves
as a dedicated local resource for utilities such as HUU. Images can be
pulled from a file share (NFS/CIFS) and uploaded to the cards for future
use.
Integrated management
processor
Baseboard Management Controller (BMC) running Cisco Integrated
Management Controller (CIMC) firmware.
Depending on your CIMC settings, the CIMC can be accessed through the 1GE
dedicated management port, the 1GE/10GE LOM ports, or a Cisco virtual
interface card (VIC).
CIMC manages certain components within the server, such as the Cisco 12G
SAS HBA.
Table 1 Capabilities and Features (continued)
Capability/Feature Description
NOTE: SD cards and M.2 SSDs cannot be mixed. See details for
RAID functionality in the ORDER M.2 SATA SSDs (OPTIONAL)
section.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES
10
Storage controller Embedded RAID (software RAID)
Supports up to eight SATA-only drives
Requires a SATA interposer board
Cisco 12G SAS RAID controller card with internal SAS connectivity.
Supports up to 10 internal SAS/SATA drives
Plugs into a dedicated RAID controller slot
Supports RAID 0, 1, 5, 6, 10, 50, 60 and JBOD mode
Cisco 12G SAS HBA (JBOD/Pass-through Mode)
Supports up to 10 SAS/SATA internal drives
Plugs into the dedicated RAID controller slot
Cisco 12G 9400-8e SAS HBA
• Supports external JBOD attach
Plugs into an appropriate riser slot (up to two supported)
•No RAID support
Modular LAN on
Motherboard (mLO
M)
slot
The dedicated mLOM slot on the motherb
oard can flexibly accommodate the
following cards:
Cisco Virtual Interface Cards
Quad Port Intel i350 1GbE RJ45 Network Interface Card (NIC)
NOTE: The four Intel i350 ports are provided on an optional card
that plugs into the mLOM slot, and are separate from the two
embedded (on the motherboard) LAN ports
UCSM Unified Computing System Manager (UCSM) runs in the Fabric Interconnect
and automatically discovers and provisions some of the server components.
Table 1 Capabilities and Features (continued)
Capability/Feature Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
11
CONFIGURING the SERVER
CONFIGURING the SERVER
Follow these steps to configure the Cisco UCS C220 M5 SFF Rack Server:
STEP 1 VERIFY SERVER SKU, page 12
STEP 2 SELECT CPU(s), page 13
STEP 3 SELECT MEMORY, page 18
STEP 4 SELECT RAID CONTROLLERS, page 25
STEP 5 SELECT DRIVES, page 30
STEP 6 SELECT PCIe OPTION CARD(s), page 35
STEP 7 ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES, page 39
STEP 8 ORDER GPU CARDS (OPTIONAL), page 40
STEP 9 ORDER POWER SUPPLY, page 41
STEP 10 SELECT POWER CORD(s), page 42
STEP 11 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT
ARM, page 45
STEP 12 SELECT MANAGEMENT CONFIGURATION (OPTIONAL), page 46
STEP 13 SELECT SERVER BOOT MODE (OPTIONAL), page 47
STEP 14 ORDER SECURITY DEVICES (OPTIONAL), page 48
STEP 15 SELECT LOCKING SECURITY BEZEL (OPTIONAL), page 49
STEP 16 ORDER CISCO SD CARD MODULE (OPTIONAL), page 50
STEP 17 ORDER M.2 SATA SSDs (OPTIONAL), page 51
STEP 18 ORDER INTERNAL MICRO-SD CARD MODULE (OPTIONAL), page 53
STEP 19 ORDER OPTIONAL USB 3.0 DRIVE, page 54
STEP 20 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 55
STEP 21 SELECT OPERATING SYSTEM MEDIA KIT, page 59
STEP 22 SELECT SERVICE and SUPPORT LEVEL, page 60
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
12
STEP 1 VERIFY SERVER SKU
Verify the product ID (PID) of the server as shown in Ta b l e 2.
Table 2 PID of the C220 M5 SFF Rack Base Server
Product ID (PID) Description
UCSC-C220-M5SX UCS C220 M5 - 10 SFF front drives with no CPU, mem
ory, HDD, PCIe cards, or
power supply. All drives can be SAS/SATA HDDS or SSDs or optionally bays 1
and/or 2 can be NVMe PCIe SSDs and the rest can be HDDs or SSDs.
UCSC-C220-M5SN UCS C220 M5 - 10 SFF front drives (
NVMe PCIe SSDs only) with no CPU, memory,
HDD, PCIe cards, or power supply
The Cisco UCS C220 M5 SFF server:
Does not include power supply, CPU, DIMM memory, hard disk drives (HDDs), solid-state
drives (SSDs), SD cards, tool-less rail kit, plug-in PCIe cards, or Intel® Optane™ Persistent
Memory.
NOTE: Use the steps on the following pages to configure the server with
the components that you want to include.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
13
CONFIGURING the SERVER
STEP 2 SELECT CPU(s)
The standard CPU features are:
2
nd
Generation Intel
®
Xeon
®
scalable family CPUs
Intel
®
C621 series chipset
Cache size of up to 38.5 MB
Select CPUs
The available CPUs are listed in Ta b l e 3
Table 3 Available CPUs
Product ID (PID)
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores
UPI
1
Links
(GT/s)
Highest
DDR4 DIMM
Clock
Support
(MHz)
2
Workload/Processor type
Cisco Recommended CPUs
3
(2
nd
Generation Intel
®
Xeon
®
Processors)
UCS-CPU-I8276 2.2 165 38.50 28 3 x 10.4 2933 Oracle, SAP
UCS-CPU-I8260 2.4 165 35.75 24 3 x 10.4 2933 Microsoft Azure Stack
UCS-CPU-I6262V 1.9 135 33.00 24 3 x 10.4 2400 Virtual Server infrastructure
or VSI
UCS-CPU-I6248R 3.0 205 35.75 24 2 x 10.4 2933
UCS-CPU-I6248 2.5 150 27.50 20 3 x 10.4 2933 VDI, Oracle, SQL, Microsoft
Azure Stack
UCS-CPU-I6238R 2.2 165 38.50 28 2 x 10.4 2933 Oracle, SAP (2-Socket TDI
only), Microsoft AzureStack
UCS-CPU-I6238 2.1 140 30.25 22 3 x 10.4 2933 SAP
UCS-CPU-I6230R 2.1 150 35.75 26 2 x 10.4 2933 Virtual Server
Infrastructure, Data
Protection, Big Data,
Splunk, Microsoft
AzureStack
UCS-CPU-I6230 2.1 125 27.50 20 3 x 10.4 2933 Big Data, Virtualization
UCS-CPU-I5220R 2.2 125 35.75 24 2 x 10.4 2666 Virtual Server
Infrastructure, Splunk,
Microsoft Azure Stack
UCS-CPU-I5220 2.2 125 24.75 18 2 x 10.4 2666 HCI
UCS-CPU-I5218R 2.1 125 27.50 20 2 x 10.4 2666 Virtual Server
Infrastructure, Data
Protection, Big Data,
Splunk, Scale-out Object
Storage, Microsoft
AzureStack
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
14
UCS-CPU-I5218 2.3 125 22.00 16 2 x 10.4 2666 Virtualization, Microsoft
Azure Stack, Splunk, Data
Protection
UCS-CPU-I4216 2.1 100 22.00 16 2 x 9.6 2400 Data Protection, Scale Out
Storage
UCS-CPU-I4214R 2.4 100 16.50 12 2 x 9.6 2400
Data Protection, Splunk,
Scale-out Object Storage,
Microsoft AzureStack
UCS-CPU-I4214 2.2 85 16.50 12 2 x 9.6 2400 Data Protection, Scale Out
Storage
UCS-CPU-I4210R 2.4 100 13.75 10 2 x 9.6 2400
Virtual Server
Infrastructure, Data
Protection, Big Data, Splunk
UCS-CPU-I4210 2.2 85 13.75 10 2 x 9.6 2400 Virtualization, Big Data,
Splunk
8000 Series Processor
UCS-CPU-I8280L 2.7 205 38.50 28 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8280 2.7 205 38.50 28 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8276L 2.2 165 38.50 28 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8276 2.2 165 38.50 28 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8270 2.7 205 35.75 26 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8268 2.9 205 35.75 24 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8260Y 2.4 165 35.75 24/20/
16
3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8260L 2.4 165 35.75 24 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8260 2.4 165 35.75 24 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I8253 2.2 125 22.00 16 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
6000 Series Processor
UCS-CPU-I6262V 1.9 135 33.00 24 3 x 10.4 2400
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6258R 2.7 205 38.50 28 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6254 3.1 200 24.75 18 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6252 2.1 150 35.75 24 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6248R 3.0 205 35.75 24 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6248 2.5 150 27.50 20 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6246R 3.4 205 35.75 16 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6246 3.3 165 24.75 12 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6244 3.6 150 24.75 8 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
Table 3 Available CPUs
Product ID (PID)
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores
UPI
1
Links
(GT/s)
Highest
DDR4 DIMM
Clock
Support
(MHz)
2
Workload/Processor type
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
15
CONFIGURING the SERVER
UCS-CPU-I6242R 3.1 205 35.75 20 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6242 2.8 150 22.00 16 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6240R 2.4 165 35.75 24 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6240Y 2.6 150 24.75 18/14/
8
3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6240L 2.6 150 24.75 18 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6240 2.6 150 24.75 18 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6238R 2.2 165 38.50 28 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6238L 2.1 140 30.25 22 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6238 2.1 140 30.25 22 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6234 3.3 130 24.75 8 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6230R 2.1 150 35.75 26 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6230N 2.3 125 27.50 20 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6230 2.1 125 27.50 20 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6226R 2.9 150 22.00 16 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6226 2.7 125 19.25 12 3 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I6222V 1.8 115 27.50 20 3 x 10.4 2400
2
nd
Gen Intel
®
Xeon
®
5000 Series Processor
UCS-CPU-I5222 3.8 105 16.50 4 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5220S 2.6 125 19.25 18 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5220R 2.2 150 35.75 24 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5220 2.2 125 24.75 18 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5218R 2.1 125 27.50 20 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5218B 2.3 125 22.00 16 2 x 10.4 2933
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5218N 2.3 105 22.00 16 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5218 2.3 125 22.00 16 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5217 3.0 115 11.00 8 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5215L 2.5 85 13.75 10 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I5215 2.5 85 13.75 10 2 x 10.4 2666
2
nd
Gen Intel
®
Xeon
®
4000 Series Processor
UCS-CPU-I4216 2.1 100 22.00 16 2 x 9.6 2400
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I4215R 3.2 130 11.00 8 2 x 9.6 2400
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I4215 2.5 85 11.00 8 2 x 9.6 2400
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I4214R 2.4 100 16.50 12 2 x 9.6 2400
2
nd
Gen Intel
®
Xeon
®
Table 3 Available CPUs
Product ID (PID)
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores
UPI
1
Links
(GT/s)
Highest
DDR4 DIMM
Clock
Support
(MHz)
2
Workload/Processor type
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
16
Approved Configurations
(1) DIMM only configurations:
Select one or two identical CPUs listed in Ta b l e 3 on page 13
(2) DIMM/PMem Mixed Configurations:
You must select two identical CPUs listed in Tab l e 3 on page 13
Caveats
The selection of 1 or 2 CPUs depends on the desired server functionality. See the following
sections:
STEP 3 SELECT MEMORY, page 18
UCS-CPU-I4214 2.2 85 16.50 12 2 x 9.6 2400
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I4210R 2.4 100 13.75 10 2 x 9.6 2400
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I4210 2.2 85 13.75 10 2 x 9.6 2400
2
nd
Gen Intel
®
Xeon
®
UCS-CPU-I4208 2.1 85 11.00 8 2 x 9.6 2400
2
nd
Gen Intel
®
Xeon
®
3000 Series Processor
UCS-CPU-I3206R 1.9 85 11.00 8 2 x 9.6 2133
2
nd
Gen Intel
®
Xeon
®
CAUTION: For systems configured with 2
nd
Gen Intel
®
Xeon
®
205W R-series processors,
operating above 30
o
C [86
o
F], a fan fault or executing workloads with extensive use of heavy
instructions sets like Intel
®
Advanced Vector Extensions 512 (Intel
®
AVX-512), may assert
thermal and/or performance faults with an associated event recorded in the System Event Log
(SEL).
Notes:
1. UPI = Ultra Path Interconnect. 2-socket servers support only 2 UPI performance, even if the CPU
supports 3 UPI.
2. If higher or lower speed DIMMs are selected than what is shown in Table 4 on page 19 for a given
CPU speed, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM
clock.
3. For details on memory support for processor classes and CPU modes, see SPARE PARTS, page 75
UCS-CPU-I6258R - Intel 6258R 2.7GHz/205W 28C/38.50MB DDR4 2933MHz
UCS-CPU-I6248R - Intel 6248R 3.0GHz/205W 24C/35.75MB DDR4 2933MHz
UCS-CPU-I6246R - Intel 6246R 3.4GHz/205W 16C/35.75MB DDR4 2933MHz
UCS-CPU-I6242R - Intel 6242R 3.1GHz/205W 20C/35.75MB DDR4 2933MHz
Table 3 Available CPUs
Product ID (PID)
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores
UPI
1
Links
(GT/s)
Highest
DDR4 DIMM
Clock
Support
(MHz)
2
Workload/Processor type
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
17
CONFIGURING the SERVER
STEP 4 SELECT RAID CONTROLLERS, page 25
STEP 5 SELECT DRIVES, page 30
STEP 6 SELECT PCIe OPTION CARD(s), page 35
NOTE: See SELECT MEMORY, page 18 for details on the compatibility of CPUs and
DIMM speeds.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
18
STEP 3 SELECT MEMORY
The available memory for the C220 M5 SFF is as follows:
Clock speed: Up to 2933 MHz; See available CPUs and their associated DDR4 DIMM maximum
clock support in
Tab l e 3.
Rank per DIMM: 1, 2, 4, or 8
Operational voltage: 1.2 V
Registered ECC DDR4 DIMMS (RDIMMs), Load-reduced DIMMs (LRDIMMs), or Intel® Optane™
Persistent Memory Modules (PMem)
Memory is organized with six memory channels per CPU, with up to two DIMMs per channel, as
shown in
Figure 4.
Figure 4 C220 M5 SFF Memory Organization
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
19
CONFIGURING the SERVER
Select DIMMs and Memory Mirroring
Select the memory configuration and whether or not you want the memory mirroring option.
The available memory DIMMs and mirroring option are listed in Ta b l e 4.
NOTE: When memory mirroring is enabled, the memory subsystem simultaneously
writes identical data to two channels. If a memory read from one of the channels
returns incorrect data due to an uncorrectable memory error, the system
automatically retrieves the data from the other channel. A transient or soft error in
one channel does not affect the mirrored data, and operation continues unless there
is a simultaneous error in exactly the same location on a DIMM and its mirrored
DIMM. Memory mirroring reduces the amount of memory available to the operating
system by 50% because only one of the two populated channels provides data.
Table 4 Available DDR4 DIMMs
Product ID (PID) PID Description Voltage
Ranks
/DIMM
UCS-ML-256G8RW
1
256 GB DDR4-3200MHz LRDIMM 8Rx4 (16Gb) (3DS) 1.2 V 8
UCS-ML-128G4RW
1
128 GB DDR4-3200MHz LRDIMM 4Rx4 (16Gb) (non-3DS)
1.2 V 4
UCS-MR-X64G2RW
1
64 GB DDR4-3200MHz RDIMM 2Rx4 (16Gb) 1.2 V 2
UCS-MR-X32G2RW
1
32 GB DDR4-3200MHz RDIMM 2Rx4 (8Gb) 1.2 V 2
UCS-MR-X16G1RW
1
16 GB DDR4-3200MHz RDIMM 1Rx4 (8Gb) 1.2 V 1
Intel
®
Optane™ Persistent Memory Product
UCS-MP-128GS-A0 Intel® Optane™ Persistent Memory, 128GB, 2666 MHz
UCS-MP-256GS-A0 Intel® Optane™ Persistent Memory, 256GB, 2666 MHz
UCS-MP-512GS-A0 Intel® Optane™ Persistent Memory, 512GB, 2666 MHz
Intel
®
Optane™ Persistent Memory Product Operational Modes
UCS-DCPMM-AD App Direct Mode
UCS-DCPMM-MM Memory Mode
Memory Mirroring Option
N01-MMIRROR Memory mirroring option
Notes:
1. DDR4-3200MHz replacement part numbers will operate at the maximum speed of the Intel 2nd generation Xeon
Scalable processor memory interface, ranging from 2133 MHz to 2933 MHz.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
20
Approved Configurations
(1) 1-CPU configuration without memory mirroring:
Select from 1 to 12 DIMMs.
1 (A1)
2 (A1, B1)
3 (A1, B1, C1)
4 (A1, B1); (D1, E1)
6 (A1, B1); (C1, D1); (E1, F1)
8 (A1, B1); (D1, E1); (A2, B2); (D2, E2)
12 (A1, B1); (C1, D1); (E1, F1); (A2, B2); (C2, D2); (E2, F2)
(2) 1-CPU configuration with memory mirroring:
Select 4, 6, 8, or 12 identical DIMMs. The DIMMs will be placed by the factory as shown in the
following table.
4 (A1, B1); (D1, E1)
6 (A1, B1, C1); (D1, E1, F1)
8 (A1, A2, B1, B2); (D1, D2, E1, E2)
12 (A1, A2, B1, B2, C1, C2); (D1, D2, E1, E2, F1, F2)
Select the memory mirroring option (N01-MMIRROR) as shown in Ta bl e 4 on page 19.
CPU 1 DIMM Placement in Channels
(for identically ranked DIMMs)
CPU 1 DIMM Placement in Channels
(for identical ranked DIMMs)
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
21
CONFIGURING the SERVER
(3) 2-CPU configuration without memory mirroring:
Select from 1 to 12 DIMMs per CPU.
CPU 1 DIMM Placement in Channels
(for identical ranked DIMMs)
CPU 2 DIMM Placement in Channels
(for identical ranked DIMMs)
CPU 1 CPU 2
1 (A1) (G1)
2 (A1, B1) (G1, H1)
3 (A1, B1, C1) (G1, H1, J1)
4 (A1, B1); (D1, E1) (G1, H1); (K1, L1)
6 (A1, B1); (C1, D1);
(E
1, F1)
(G1, H1); (J1, K1); (L1, M1)
8 (A1, B1); (D1, E1);
(A
2, B2); (D2, E2)
(G1, H1); (K1, L1); (G2, H2); (K2, L2)
1
2
(A1, B1); (C1, D1); (E1, F1); (A2, B2); (C2, D2);
(E
2, F2)
(G1, H1); (J1, K1); (L1, M1); (G2, H2); (J2, K2);
(L2, M2)
(4) 2-CPU configuration with memory mirroring:
Select 8,12 16, or 24 identical DIMMs per CPU. The DIMMs will be placed by the factory as
shown in the following table.
CPU 1 DIMM Placement in Channels
(for identical ranked DIMMs)
CPU 2 DIMM Placement in Channels
(for identical ranked DIMMs)
CPU 1 CPU 2
8 (A1,B1); (D1,E1) (G1, H1); (K1, L1)
12 (A1, B1, C1); (D1, E1, F1) (G1, H1, J1); (K1, L1, M1)
16 (A1, A2, B1, B2); (D1, D2, E1, E2) (G1, G2, H1, H2); (K1, K2, L1, L2)
24 (A1, A2, B1, B2, C1, C2); (D1, D2, E1, E2, F1,
F2
)
(G1, G2, H1, H2, J1, J2); (K1, K2, L1, L2, M1,
M2)
Select the memory mirroring option (N01-MMIRROR) as shown in Ta bl e 4 on page 19.
NOTE:
System performance is optimized when the DIMM type and quantity are equal
for both CPUs, and when all channels are filled equally across the CPUs in the
server.
DIMM mixing is not allowed when PMem are installed; in these cases, all DIMMs
must be the same type and size.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
22
System Speed
Memory will operate at the maximum speed of the Intel Xeon Scalable processor memory controller, ranging
from 2133 MHz to 2933 MHz for M5 servers. Check CPU specifications for supported speeds
NOTE: Detailed mixing DIMM configurations are described in Cisco UCS Cisco UCS
C220/C240/B200 M5 Memory Guide
Table 5 Intel® Optane™ Persistent Memory Modes
Intel® Optane™ Persistent Memory
App Direct Mode: PMem operates as a solid-state disk storag
e device. Data is saved and is
non-volatile. Both PMem and DIMM capacity counts towards CPU tiering
(both PMem and DIMM capacities count towards the CPU capacity limit)
Memory Mode:
1
PMem operates as a 100% memory module. Data is volatile and DRAM acts
as a cache for PMem. Only PMem capacity counts towards CPU tiering (only
the PMem capacity counts towards the CPU capacity limit). This is the
factory default mode.
Mix Mode: DRAM as cache. Only PMem capacity counts towards CPU tiering (only the
PMem c
apacity counts towards the CPU capacity limit)
Tab l e 6 2
nd
Generation Intel
®
Xeon
®
Scalable Processor DIMM and PMem
1
Physical Configuration
DIMM to PMem
Count
CPU 1
iMC1 iMC0
Channel 2 Channel 1 Channel 0 Channel 2 Channel 1 Channel 0
F2 F1 E2 E1 D2 D1 C2 C1 B2 B1 A2 A1
6 - 2 DIMM DIMM PMem DIMM DIMM DIMM PMem DIMM
6 - 4
DIMM PMem DIMM PMem DIMM DIMM PMem DIMM PMem DIMM
6 - 6 PMem DIMM PMem DIMM PMem DIMM PMem DIMM PMem DIMM PMem DIMM
DIMM to PMem
Count
CPU 2
iMC1
iMC0
Channel 2 Channel 1 Channel 0 Channel 2 Channel 1 Channel 0
M2 M1 L2 L1 K2 K1 J2 J1 H2 H1 G2 G1
6 - 2 DIMM DIMM PMem DIMM DIMM DIMM PMem DIMM
6 - 4
DIMM PMem DIMM PMem DIMM DIMM PMem DIMM PMem DIMM
6 - 6 PMem DIMM PMem DIMM PMem DIMM PMem DIMM PMem DIMM PMem DIMM
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
23
System Speed
See Ta b l e 5 for PMem memory modes.
Notes:
1. For Memory Mode, the Intel-recommended DIMM to PMem capacity ratio in the same CPU channel is from 1:2 to
1:16. So if you use a 128 GB DIMM in a channel, you could use a 512 GB PMem for a 1:6 capacity ratio. If you use
a 32 GB DIMM in a channel, you could use a 512 GB PMem for a 1:16 capacity ratio. There are several other
combinations possible
Notes:
1. All systems must be fully populated with two CPUs when using PMem at this time.
NOTE: There are three possible memory configurations for each CPU when combining
DIMMs and PMem, and the configurations must be the same for each CPU:
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
24
For detailed Intel PMem configurations, refer to the following document:
Cisco UCS C220 M5 Server Installation and Serv
ice Guide
For detailed DIMM/PMem informations, refer to
Cisco UCS C220/C240/B200 M5 Memory Guide
6 DIMMs and 2 PMem, or
6 DIMMs and 4 PMem, or
6 DIMMs and 6 PMem
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
25
System Speed
STEP 4 SELECT RAID CONTROLLERS
RAID Controller Options (internal HDD/SSD support)
NOTE: NVMe drives are controlled directly by CPU2 and not by any RAID controller.
Embedded Software RAID
The default RAID configuration is embedded software RAID, which supports only SATA HDDs and
enterprise value SATA SSDs (RAID 0, 1, 10). A maximum of 8 SATA drives are supported with
embedded software RAID. Embedded RAID requires a SATA interposer board.
NOTE: The embedded software RAID is limited to Windows and Linux operating
systems only. There is no VMware support for embedded software RAID.
Cisco 12G SAS RAID Controller
You can choose a Cisco 12G SAS RAID controller, which plugs into a dedicated internal RAID controller card
connector. This RAID controller includes a 2 GB cache and supports RAID 0, 1, 5, 6, 10, 50, 60, JBOD mode
and SRAID0.
NOTE: The number of RAID groups (virtual drives) supported per RAID controller is
as follows:
Embedded RAID = 8
Cisco 12G SAS RAID controller = 64
SAS HBA (internal HDD/SSD/JBOD support)
You can choose a SAS HBA for JBOD or Pass-through mode support:
The Cisco 12G SAS HBA plugs into an internal dedicated RAID controller connector.
SAS HBA (external JBOD support)
In addition to a RAID controller or JBOD controller for internal drives, you can choose the
following SAS HBA for external JBOD drive connectivity (non-RAID):
Cisco 9400-8e 12G SAS HBA for external JBOD attach. You can have up to two of these, one
in each of the PCIe slots in the rear panel. Each one controls up to 8 external drives.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
26
RAID Volumes and Groups
When creating each RAID volume, follow these guidelines:
Use the same capacity for each drive in each RAID volume
For embedded software RAID:
Use only SATA HDDs or SATA SSDs
Embedded software RAID has two ports and ea
ch port can control 4 drives, for 8
drives total.
Each set of 4 SATA HDDs for a port mus
t be in separate RAID volumes.
You cannot mix drives across ports to create a RAID volume.
For more details, see Embedded Software RAID.
For the Cisco 12G SAS RAID controller upgrade:
Use either all SAS/SATA HDDs, or all SAS SSDs, or all SA
TA SSDs in each RAID volume
Select RAID Controller Options
Select one of the following:
Embedded software RAID (this is the default if no other selection is made), or
One Cisco 12G SAS RAID controller or Cisco 12G SAS HBA (see Tab l e 7)
NOTE: The UCSC-C220-M5SN does not support embedded RAID.
NOTE: The default RAID solution is embedded software RAID that supports a limited
number of drives, operating systems, and virtualized environments. For a more
comprehensive RAID solution, choose a controller from
Ta b l e 7.
Table 7 Hardware Controller Options
Product ID (PID) PID Description
Controllers for Internal Drives
Note that if the following Cisco 12G SAS RAID controller o
r Cisco 12G SAS HBA controller is selected,
it is factory-installed in the dedicated internal slot.
UCSC-RAID-M5 Cisco 12G SAS RAID Controller with 2GB FBWC
Supports up to 10 internal SAS/SATA HDDs and SAS/SATA SSDs.
Supports RAID 0, 1, 5, 6, 10, 50, 60, and JBOD mode. Supports running
mixed RAID and JBOD mode.
For all self-encrypting drives (SED), standalone Management (CIMC/UCSM)
is supported for configuring and managing local keys. For now, SED drives
are managed with local key management only. Third-party key
management will be supported (KMIP compliant).
UCSC-SAS-M5 Cisco 12G SAS HBA
Supports up to 10 internal SAS HDDs and SAS/SATA SSDs
Supports JBOD mode only (no RAID functionality). Ideal for SDS (Software
Defined Storage) applications. It is also ideal for environments demanding
the highest IOPs (for external SSD attach), where a RAID controller can be
an I/O bottleneck.
No SED drive support
Controller for External Drives (plugs into PCIe slot)
UCSC-9400-8E Cisco 12G 9400-8e 12G SAS HBA for external JBOD attach. You can install up to
two of these
and place them in the rear PCIe slots.
RAID Configuration Options (not available for Cisco 12
G SAS HBA or embedded software RAID)
R2XX-SRAID0 Enable Single Disk Raid 0 Setting
R2XX-RAID0 Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1 Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly t
wo drives with the same size, speed,
capacity.
R2XX-RAID5 Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of
three drives of the same size,
speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of
four drives of the same size,
speed, capacity.
R2XX-RAID10 Factory preconfigured RAID option
Enable RAID 10 Setting. Requires a even number of drives (m
inimum of four
drives) of the same size, speed, capacity.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
27
System Speed
NOTE:
Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in Tab l e 7.
For Cisco SAS 9400-8e 12G SAS HBA external drive enclosure support, see the
enclosure section of the compatibility list at the following link:
https://www.broadcom.com/support/s
torage/interop-compatibility
Customers should contact their storage vendor for technical support related to
e
xternal JBOD enclosures.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
28
Approved Configurations
Embedded software RAID (the default) supports up to 8 internal SATA HDDs with RAID 0, 1,
10 support.
The Cisco 12G SAS RAID controller upgrade option supports up to 10 internal drives with up
to RAID 0, 1, 10, 5, 6, 50, 60 and JBOD mode support.
The Cisco 12G SAS HBA upgrade option supports up to 10 internal drives with JBOD support.
Up to two Cisco 12G 9400-8e SAS HBA external drive PCIe controller cards can be installed
simultaneously with the Cisco 12G SAS Modular RAID controller card (UCSC-RAID-M5) or Cisco
12 Gbps Modular SAS HBA (UCSC-SAS-M5).
See Ta b l e 8 for a summary of the supported co
ntroller configuration options.
Table 8 Supported Controller Configurations for C220 M5 SFF Server
#
CPUs
Embedded
RAID
Cisco 12G SAS RAID Controller
or Cisco 12G SAS HBA (
only
one can be installed
at a time)
Cisco 12G
9400-8e
12G SAS
HBA
MAX#
Drives
Supported
RAID Support
Internal Drive
Types Allowed
Cisco 12G SAS
RAID
Controller
Cisco 12G SAS
HBA
1 Enabled Not allowed Not allowed
Up to two
installed in
rear PCIe
slots
8 internal
SATA only, 8
or 16
external
0, 1, 10 (SATA
only)
SATA
HDDs/Enterprise
V
alue SATA SSDs
1
Not
allowed
Installed in
dedicated slot
Installed in
dedicated slot
Up to two
installed in
rear PCIe
slots
10 internal,
8 or 16
external
0,1,10,5,6,50,
60 JBOD
(12G SAS
RAID), JBOD
(SAS HBA)
SAS/SATA HDDs,
SAS/SATA SSDs
Only one of the above can be
installed at a time
2 Enabled Not allowed Not allowed
Up to two
installed in
rear PCIe
slots
8 internal
SATA only, 8
or 16
external
0, 1, 10 (SATA
only)
SATA
HDDs/Enterprise
Va
lue SATA SSDs
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
29
System Speed
2
Not
allowed
Installed in
dedicated slot
Installed in
dedicated slot
Up to two
installed in
rear PCIe
slots
10 internal,
8 or 16
external
0,1,10,5,6,50,
60 JBOD
(12G SAS
RAID), JBOD
(SAS HBA)
SAS/SATA HDDs,
SAS/SATA SSDs,
NVMe SSDs
Only one of the above can be
installed at a time
NOTE: There is no RAID support for NVMe. NVMe drives are controlled directly by
CPU2. In an embedded RAID configuration, only embedded software RAID (0, 1, 10) is
supported, and AHCI mode is not supported.
Table 8 Supported Controller Configurations for C220 M5 SFF Server (continued)
#
CPUs
Embedded
RAID
Cisco 12G SAS RAID Controller
or Cisco 12G SAS HBA (only
one can be installed
at a time)
Cisco 12G
9400-8e
12G SAS
HBA
MAX#
Drives
Supported
RAID Support
Internal Drive
Types Allowed
Cisco 12G SAS
RAID
Controller
Cisco 12G SAS
HBA
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
30
STEP 5 SELECT DRIVES
The standard disk drive features are:
2.5-inch small form factor
Hot-pluggable
Drives come mounted in sleds
Select Drives
The available drives are listed in Ta bl e 9.
Table 9 Available Hot-Pluggable Sled-Mounted Drives
(UCSC-C220-M5S (10-drive system) and UCSC-C220-M5SN (10-drive NVMe only system)
Product ID (PID) PID Description
Drive
Type
Capacity
HDDs
HDDs (15K RPM)
UCS-HD300G15K12N 300 GB 12G SAS 15K RPM SFF HDD SAS 300 GB
UCS-HD600G15K12N 600 GB 12G SAS 15K RPM SFF HDD SAS 600 GB
UCS-HD900G15K12N 900 GB 12G SAS 15K RPM SFF HDD SAS 900 GB
HDDs (10K RPM)
UCS-HD300G10K12N 300 GB 12G SAS 10K RPM SFF HDD SAS 300 GB
UCS-HD600G10K12N 600 GB 12G SAS 10K RPM SFF HDD SAS 600 GB
UCS-HD12TB10K12N 1.2 TB 12G SAS 10K RPM SFF HDD SAS 1.2 TB
UCS-HD18TB10K4KN
1
1.8 TB 12G SAS 10K RPM SFF HDD (4K) SAS 1.8 TB
UCS-HD24TB10K4KN
1
2.4 TB 12G SAS 10K RPM SFF HDD (4K) SAS 2.4 TB
HDDs (7.2K RPM)
UCS-HD1T7K12N 1 TB 12G SAS 7.2K RPM SFF HDD SAS 1 TB
UCS-HD2T7K12N 2 TB 12G SAS 7.2K RPM SFF HDD SAS 2 TB
UCS-HD1T7K6GAN 1 TB 6G SATA 7.2K RPM SFF HDD SAS 1 TB
SAS/SATA SSDs
2
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day))
3
SAS SSDs
UCS-SD800GK3X-EP 800 GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 800 GB
UCS-SD16TK3X-EP 1.6 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 1.6 TB
UCS-SD32TK3X-EP 3.2 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 3.2 TB
UCS-SD32TKA3X-EP 3.2TB 2.5in Enter Perf 12G SAS Kioxia G2 SSD (3X) SAS 3.2 TB
SATA SSDs
UCS-SD480G63X-EP 480GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)
(Intel S4600/S4610)
SATA 480 GB
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
31
System Speed
UCS-SD960G63X-EP 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)
(Intel S4600/S4610)
SATA 960 GB
UCS-SD19T63X-EP 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance)
(Intel S4600/S4610)
SATA 1.9 TB
UCS-SD19TBM3X-EP 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance) SATA 1.9 TB
UCS-SD960GBM3X-EP 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) SATA 960 GB
UCS-SD480GBM3X-EP 480GB 2.5in Enterprise Performance 6GSATA SSD(3X endurance) SATA 480 GB
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))
4
SAS SSDs
UCS-SD960GK1X-EV 960 GB 2.5 inch Enterprise Value 12G SAS SSD SAS 960 GB
UCS-SD19TK1X-EV 1.9 TB 2.5 inch Enterprise Value 12G SAS SSD SAS 1.9 TB
UCS-SD38TK1X-EV 3.8 TB 2.5 inch Enterprise Value 12G SAS SSD SAS 3.8 TB
UCS-SD76TK1X-EV 7.6 TB 2.5 inch Enterprise Value 12G SAS SSD SAS 7.6 TB
UCS-SD15TK1X-EV 15.3 TB 2.5 inch Enterprise Value 12G SAS SSD SAS 15.3 TB
SATA SSDs
UCS-SD76TBM1X-EV 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
UCS-SD38TBM1X-EV 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD19TBM1X-EV 1.9TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9 TB
UCS-SD16TBM1X-EV 1.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.6 TB
UCS-SD960GBM1X-EV 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCS-SD480GBM1X-EV 480 GB 2.5 inch Enterprise Value 6G SATA SSD SATA 480 GB
UCS-SD240GBM1X-EV 240GB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD120GM1X-EV 120 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100
/5200/5300)
SATA 120 GB
UCS-SD19T61X-EV 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung
PM863A/PM883)
SATA 1.9 TB
UCS-SD38T61X-EV 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung
PM863A/PM883)
SATA 3.8 TB
UCS-SD480G6I1X-EV 480GB 2.5 inch Enterprise Value 6G SATA SSD (Intel
S4500/S4510/5300)
SATA 480 GB
UCS-SD960G6I1X-EV 960GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4510) SATA 960 GB
UCS-SD38T6I1X-EV 3.8TB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4510) SATA 3.8 TB
UCS-SD960G6S1X-EV 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCS-SD19T6S1X-EV 1.9TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9 TB
UCS-SD38T6S1X-EV 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD76T6S1X-EV 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
Self-Encrypted Drives (SED)
SAS
UCS-HD600G15NK9 600 GB 12G SAS 15K RPM SFF HDD (SED) FIPS140-2 SAS 600 GB
Table 9 Available Hot-Pluggable Sled-Mounted Drives (continued)
(UCSC-C220-M5S (10-drive system) and UCSC-C220-M5SN (10-drive NVMe only system)
Product ID (PID) PID Description
Drive
Type
Capacity
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
32
UCS-HD24T10NK9 2.4 TB 12G SAS 10K RPM SFF HDD (4K) (SED) FIPS140-2 SAS 2.4 TB
UCS-HD18T10NK9 1.8 TB 12G SAS 10K RPM SFF HDD (4K format, SED) FIPS140-2 SAS 1.8 TB
UCS-HD12T10NK9 1.2 TB 12G SAS 10K RPM SFF HDD (SED) FIPS140-2 SAS 1.2 TB
UCS-SD960GBKNK9 960GB 2.5" Enterprise value 12G SAS SSD (1X DWPD, SED) FIPS140-2 SAS 960 GB
UCS-SD38TBKNK9 3.8TB 2.5" Enterprise value 12G SAS SSD (1X DWPD, SED) FIPS140-2 SAS 3.8 TB
UCS-SD800GBKNK9 800GB 2.5" Enterprise performance 12GSAS SSD(3X DWPD,SED)
FIPS140-2
SAS 800 GB
UCS-SD16TBKNK9 1.6TB 2.5" Enterprise performance 12GSAS SSD(3X DWPD,SED)
FIPS140-2
SAS 1.6 TB
UCS-SD76TBKNK9 7.6TB Enterprise value SAS SSD (1X DWPD, SED-FIPS) FIPS140-2 SAS 7.6 TB
PCIe/NVMe SFF (2.5-inch) drives
2,5
UCSC-NVMEXPB-I375 Cisco 375GB 2.5in Intel Optane NVMe Extreme Performance SSD NVMe 375 GB
UCSC-NVMEXP-I750 Cisco 750GB 2.5in Intel Optane NVMe Extreme Performance NVMe 750 GB
UCS-NVME4-1920 1.9TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe NVMe 1,9 TB
UCS-NVME4-3840 3.8TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe NVMe 3.8 TB
UCS-NVME4-7680 7.6TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe NVMe 7.6 TB
UCS-NVME4-1536 15.3TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe NVMe 15.3 TB
UCS-NVME4-1600 1.6TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X) NVMe 1.6 TB
UCS-NVME4-3200 3.2TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X) NVMe 3.2 TB
UCS-NVME4-6400 6.4TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X) NVMe 6.4 TB
UCS-NVMEQ-1536 15.3TB 2.5in U.2 15mm P5316 Hg Perf Low End NVMe NVMe 15.3 TB
UCS-NVMEM6-W3200 3.2TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance NVMe 3.2 TB
UCS-NVMEM6-W7680 7.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance NVMe 7.6 TB
UCS-NVMEM6-W15300 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance NVMe 15.3 TB
NOTE: Cisco uses solid state drives from a number of vendors. All solid state drives are subject to physical write limits and
have varying maximum usage limitation specifications set by the manufacturer. Cisco will not replace any solid state drives
that have exceeded any maximum usage specifications set by Cisco or the manufacturer, as determined solely by Cisco.
Notes:
1. Operating Systems supported on 4k sector size drives are as follows:
- Windows: Minimum release Win2012 and later
- Linux: Minimum release RHEL 6.5 and later
- VMware ESXI 6.5 and later is needed for 512E drive support; VMware ESXI 6.7 and later is needed for 4KN drive support.
- UEFI Mode must be used when booting from 4K sector size drives (legacy mode is not supported).
- Ensure that 4K sector size and 512 byte sector size drives are not mixed in the same RAID volume.
2. Two CPUs must be installed in order to include any number of SFF NVMe PCIe SSDs. If you choose one or two PCIe
NVMe drives, drive slots 1 and 2 at the front of the chassis are reserved for these drives (see Figure 2 on page 5 for
drive slot numbering). With the C220 M5SN, you can ONLY have NVMe PCIe SSDs (up to 10).
Table 9 Available Hot-Pluggable Sled-Mounted Drives (continued)
(UCSC-C220-M5S (10-drive system) and UCSC-C220-M5SN (10-drive NVMe only system)
Product ID (PID) PID Description
Drive
Type
Capacity
NOTE: When configuring front facing drives with spare NVMe drives, you must order
an NVMe cable (PID = CBL-NVME-220FF) along with the spare drives.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
33
System Speed
Caveats
With the UCSC-C220-M5SX you can choose only SATA HDDs when using embedded software
RAID. The UCSC-C220-M5SN does not support embedded RAID.
SFF NVMe drives are connected directly to CPU2 and not managed by the RAID controller.
You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all
SSDs in their own RAID volume.
You can mix SAS HDDs and SAS/SATA SSDs when using the Cisco 12G SAS RAID Controller or
Cisco 12G SAS HBA.
If you order any NVMe SFF drives, you must also order two CPUs.
Except HGST, Intel and Western Digital (WD) NVMe drives can be mixed anywhere in a C220
M5.
SFF NVMe drives are bootable in UEFI mode only.
NVMe HHHL drives are not bootable (see Tab l e 10 on page 35).
SED drives can be mixed with the non-SED drives in Ta b l e 9 on page 30.
3. Targeted for write centric IO applications. Supports endurance of 10 or 3 DWPD (drive writes per day). Target
applications are caching, online transaction processing (OLTP), data warehousing, and virtual desktop infrastructure
(VDI).
4. Targeted for read centric IO applications. Supports endurance of 1 DWPD (drive write per day). Target applications
are boot, streaming media, and collaboration.
5. Except HGST, Intel and Western Digital (WD) NVMe drives can be mixed anywhere in a C220 M5.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
34
Intel® Virtual RAID on CPU (Intel® VROC)
The server supports Intel® Virtual RAID on CPU (Intel® VROC). VROC is an enterprise RAID solution used with
Intel NVMe SSDs (see Ta b l e 13 for supported Intel NVMe SSDs). The Intel® V
olume Management Device
(Intel® VMD) is a controller integrated into the CPU PCIe
root complex. Intel® VMD NVMe SSDs are
connected to the CPU, which allows the full performance potential of fast Intel® Optane™ SSDs to be
realized. Intel® VROC, when implemented, replaces traditional hardware RAID host bus adapter (HBA)
cards placed between the drives and the CPU.
NOTE:
Intel® VROC is only supported with Intel drives
Intel® VROC enablement key factory pre-provisioned to BIOS - no additional licensing
required.
VROC has the following features:
Small Form Factor (SFF) drive support (only)
No battery backup (BBU) or external SuperCap needed
Software-based solution utilizing Intel SFF NVMe direct connected to Intel CPU
RAID 0/1/5/10 support
Windows, Linux, VMware OS support.
Host Tools- Windows GUI/CLI, Linux CLI.
UEFI Support- HII Utility, OBSE.
Intel VROC NVMe operates in UEFI mode only
See the instructions on setting up and managing VROC for Intel NVMe SSDs for mor
e information.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
35
System Speed
STEP 6 SELECT PCIe OPTION CARD(s)
For up-to-date server compatibility, please check the Hardware and Software compatibility list
(HCL) at
https://ucshcltool.cloudapps.cisco.com/public/.
The standard PCIe card offerings are:
Modular LAN on Motherboard (mLOM)
Virtual Interface Cards (VICs)
Network Interface Cards (NICs)
PCIe - Accelerators/Smart NICs
Host Bus Adapters (HBAs)
UCS NVMe/PCIe Add-in Storage Cards
Select PCIe Option Cards
The available PCIe option cards are listed in Tab l e 10.
Table 10 Available PCIe Option Cards
Product ID (PID) PID Description Location
Electrical
slot
Card
Height
1
Modular LAN on Motherboard (mLOM)
UCSC-MLOM-C100-04 Cisco UCS VIC 1497 Dual Port 40/100G QSFP28
CNA mLOM
mLOM x 16 N/A
UCSC-MLOM-C25Q-04 Cisco UCS VIC 1457 Quad Port 10/25G SFP28
mLOM
mLOM x 16 N/A
UCSC-MLOM-C40Q-03 Cisco UCS VIC 1387 Dual Port 40Gb QSFP+ CNA mLOM x 8 N/A
UCSC-MLOM-IRJ45 Intel i350 Quad Port 1GBase-T NIC mLOM x 8 N/A
Virtual Interface Card (VICs)
UCSC-PCIE-C100-04 Cisco UCS VIC 1495 Dual Port 40/100G QSFP28
CNA PCIe
Riser 1 or 2 x 16 HHHL
UCSC-PCIE-C40Q-03 Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA
w/RDMA
Riser 1 or 2 x 16 HHHL
UCSC-PCIE-C25Q-04 Cisco VIC 1455 VIC PCIE – Quad Port 10/25G
SFP28
Riser 1 or 2 x 16 HHHL
Network Interface Cards (NICs)
1 Gb NICs
UCSC-PCIE-IRJ45 Intel i350 Quad Port 1GBase-T NIC Riser 1 or 2 x 8
10 Gb NICs
N2XX-AIPCI01 Intel X520 Dual Port 10Gb SFP+ NIC Riser 1 or 2 x 8 HHHL
UCSC-PCIE-ID10GC Intel X550-T2 Dual Port 10GBase-T NIC Riser 1 or 2 x 8 HHHL
UCSC-PCIE-ID10GF Intel X710-DA2 Dual Port 10Gb SFP+ NIC Riser 1 or 2 x 8 HHHL
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
36
Approved Configurations
(1) 1-CPU Systems
You can select up to one of the PCIe option cards (slot 1) listed in Ta b l e 10.
(2) 2-CPU Systems
UCSC-PCIE-IQ10GF Intel X710 Quad Port 10Gb SFP+ NIC Riser 1 or 2 x 8 HHHL
UCSC-PCIE-IQ10GC Intel X710 Quad Port 10GBase-T NIC Riser 1 or 2 x 8 HHHL
25 Gb NICs
UCSC-PCIE-QD25GF Qlogic QL41212H Dual Port 25Gb NIC Riser 1 or 2 x 8 HHHL
UCSC-PCIE-ID25GF Intel XXV710 Dual Port 25Gb SFP28 NIC Riser 1 or 2 x 8 HHHL
UCSC-P-M4D25GF Mellanox MCX4121A-ACAT dual port 10/25G
SFP28 NIC
Riser 1 or 2 x 8 HHHL
UCSC-P-M5D25GF Mellanox CX-5 EN MCX512A-ACAT
2x25/10GbE SFP PCIe NIC
Riser 1 or 2 x 8 HHHL
40 Gb NICs
UCSC-PCIE-QD40GF Qlogic QL45412H Dual Port 40Gb NIC Riser 1 or 2 x 16 HHHL
UCSC-PCIE-ID40GF Intel XL710 Dual Port 40Gb QSFP+ NIC Riser 1 or 2 x 8 HHHL
100 Gb NICs
UCSC-PCIE-QS100GF Qlogic QLE45611HLCU single port 100G NIC Riser 1 or 2 x 16 HHHL
UCSC-P-M5D100GF Mellanox CX-5 MCX516A-CDAT 2x100GbE QSFP
PCIe NIC
Riser 1 or 2 x 16 HHHL
UCSC-P-M5S100GF Mellanox CX-5 MCX515A-CCAT 1x100GbE QSFP
PCIe NIC
Riser 1 or 2
x 16
HHHL
PCIe - Accelerators/Smart NICs
UCSC-P-IQAT8970 Cisco-Intel 8970 QAT Offload PCIe Adapter Riser 1 or 2 x 16 HHHL
Host Bus Adapters (HBAs)
UCSC-PCIE-QD16GF Qlogic QLE2692 Dual Port 16G Fibre Channel
HBA
Riser 1 or 2 x 8 HHHL
UCSC-PCIE-BD16GF Emulex LPe31002 Dual Port 16G Fibre Channel
HBA
Riser 1 or 2 x 8 HHHL
UCSC-PCIE-QD32GF Qlogic QLE2742 Dual Port 32G Fibre Channel
HBA
Riser 1 or 2 x 8 HHHL
UCSC-PCIE-BS32GF Emulex LPe32000-M2 Single Port 32G Fibre
Channel HBA
Riser 1 or 2 x 8 HHHL
UCSC-PCIE-BD32GF Emulex LPe32002-M2 Dual Port 32G Fibre
Channel HBA
Riser 1 or 2 x 8 HHHL
Notes:
1. HHHL= Half Height Half Length
Table 10 Available PCIe Option Cards (continued)
Product ID (PID) PID Description Location
Electrical
slot
Card
Height
1
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
37
System Speed
You can select up to two of the PCIe option cards (slots 1 and 2) listed in Ta b l e 10.
Caveats
For 1-CPU systems:
— Only the full-height PCIe slot on riser 1 (slot
1) is supported
— Only a single plug-in PCIe VIC card is supported and must be installed in slot 1 (the
ful
l-height slot). However, in addition to the one PCIe VIC card, you can also choose to
install an mLOM VIC card in the mLOM slot at the rear of the chassis.
For 2-CPU systems:
— Both PCIe slots (slots 1 and 2) are supported
— Two plug-in PCIe VIC cards can be installed in 2-CPU systems, using slots 1 and 2. In
addition, you can
order an mLOM VIC card, which is installed in the mLOM slot at the rear
of the chassis and thus have three VIC cards in operation at the same time. See Tab l e 10
on page 35 for the selection of plug-in and mL
OM VIC cards. See also Ta b l e 1 on page 7.
To help ensure that your operating system is compatible with the card you have selected, or
to see additional cards that have been qualified to work with the UCS C220 M5 server, but
are not sold on the Cisco pricelist, check the Hardware Compatibility List at this URL:
http://www.cisco.com/en/US/products/ps10477/p
rod_technical_reference_list.html
NOTE: Mixing 1300 and 1400 series VIC and MLOMs configurations is not supported.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
38
PCIe Card Configuration with 2 CPU
Below table helps in finding the right slot for the selected PCIe cards.
Table 11 PCIe Card Configuration with 2 CPU
PCIe Card Type Primary Slot Secondary Slot Alternate Slot
Cisco12G Modular RAID controller
Midplane Slot None
Cisco 12G 9460-8i Raid controller
10 None
PCIe Switch card 10 None
Cisco x16 VIC (
Cisco VIC 1385)
1 2 8, 5
Nvidia and AMD GPUs 2 8 10, 1
Other 16x PCIe I/O card 8 10 2, 1
Other 8x PCIe I/O card 9 5 8, 2, 10, 1
Cisco x16 VIC 1 2 8
NOTE:
Slot 1 only if no VIC present
When no VIC presents in the configuration, GPU primary slot could be 1
First VIC has the highest priority, then GPUs, then others.
Primary Slots are first priorities
Secondary slots are for additional card of the same type, follow the order
listed
Alternate slots can be used but may be with reduced functionality
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
39
System Speed
STEP 7 ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
These optics and cables have been tested for compatibility and are approved for use with
Intel® Ethernet Network Adapter (as of the time of this publication). For the latest update,
check the and consult Cisco Compatibility Matrix at https://tmgmatrix.cisco.com.
For list of supported optics and cables for VIC1385, VIC 1387, VIC 1440, VIC 1455, VIC 1457,
VIC 1495 and VIC 1497 refer to VIC 1300 and VIC 1400 series data sheet at the following
links:
https://www.cisco.com/c/en/us/products/c
ollateral/interfaces-modules/unified-co
mputing-system-adapters/datasheet-c78-741130.html
https://www.cisco.com/c/en/us/products/interfaces-modu
les/ucs-virtual-interface-c
ard-1387/index.html
https://www.cisco.com/c/en/us/products/col
lateral/interfaces-modules/unified-co
mputing-system-adapters/datasheet-c78-734727.html
Refer to the these links for additional Connectivity Options.
Intel: Marvell/Qlogic: Mellanox:
Product Guide 41000 series Interoperability Matrix Firmware Release Notes
Speed White Paper 45000 series Interoperability Matrix
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
40
STEP 8 ORDER GPU CARDS (OPTIONAL)
Select GPU Options
The available GPU PCIe options are listed in Ta b l e 12
Table 12 Available PCIe GPU Cards
1
Product ID (PID) PID Description Card Size Maximum cards Per node
GPU PCIe Cards
UCSC-GPU-P4 NVIDIA P4 Low Profile Single-Width 2
UCSC-GPU-T4-16 NVIDIA T4 16GB Low Profile Single-Width 2
.
NOTE:
All GPU cards must be procured from Cisco as there is a unique SBIOS ID
required by CIMC and UCSM
Caveats
GPUs cannot be mixed.
A GPU can be installed in either PCIe slot 1 or 2; however, for 1-CPU systems, only slot 1 is
available. In 2-CPU systems, matching GPUs can be installed in both slots. for the additional
information related to GPU card slots, refer to PCIe Card Configuration with 2 CPU, page
38.
The NVIDIA P4 GPU is not supported with 2
nd
Generation Intel
®
Xeon
®
Processors.
Notes:
1. Refer to C220 M5 GPU Card Installation for more details.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
41
System Speed
STEP 9 ORDER POWER SUPPLY
Power supplies share a common electrical and physical design that allows for hot-plug and
tool-less installation into M5 C-series servers. Each power supply is certified for high-efficiency
operation and offers multiple power output options. This allows users to “right-size” based on
server configuration, which improves power efficiency, lowers overall energy costs and avoids
stranded capacity in the data center. Use the power calculator at the following link to
determine the needed power based on the options chosen (CPUs, drives, memory, and so on):
http://ucspowercalc.cisco.com
Table 13 Power Supply
Product ID (PID) PID Description
UCSC-PSU1-770W 770W AC power supply for C-Series Servers Platinum
UCSC-PSU1-1050W 1050W AC power supply for C-Series servers Platinum
UCSC-PSUV2-1050DC 1050W DC power supply for C-Series servers Platinum
UCSC-PSU1-1600W 1600W AC power supply for C-Series servers Platinum
UCSC-PSU1-1050ELV 1050W AC Power Supply C-Series Enhanced Low Line Platinum
NOTE: In a server with two power supplies, both power supplies must be identical.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
42
STEP 10 SELECT POWER CORD(s)
Using Tab l e 14, select the appropriate AC power cords. You can select a minimum of no power
cords and a maximum of two.
Table 14 Available Power Cords
Product ID (PID) PID Description Images
NO-POWER-CORD ECO friendly green option, no
power cable will be shipped
Not applicable
CAB-48DC-40A-8AWG C-Series -48VDC PSU Power Cord,
3
.5M, 3 Wire, 8AWG, 40A
CAB-N5K6A-NA Power Cord, 200/240V 6A, North
America
Cordset rating: 10 A, 250 V
Length: 8.2 ft
1
86570
Plug: NEMA 6-15P
Connector:
IEC60320/C13
CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft
CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,
C13/C14, 10A/250V
CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR,
2 Meter, C13/C14,10A/250V
CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6
0320/C13, 3.0M
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
43
System Speed
CAB-250V-10A-AR Power Cord, 250V, 10A, Argentina
186571
2500 mm
Cordset rating: 10 A, 250/500 V MAX
Length: 8.2 ft
Plug:
EL 219
(IRAM 2073)
Connector:
EL 701
(IEC60320/C13)
CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug,
Australia
Plug:
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
186580
Connector:
EL 701C
(EN 60320/C15)
EL 210
(BS 1363A) 13 AMP fuse
CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC
CAB-9K10A-EU Power Cord, 250VAC 10A CEE 7/7
Plug, EU
Connector:
VSCC15
Cordset rating: 10A/16 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Plug:
M2511
186576
CAB-250V-10A-ID Power Cord, 250V, 10A, India
OVE
Cordset rating 16A, 250V
(2500mm)
Plug:
EL 208
1
87490
Connector:
EL 701
CAB-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel
Cordset rating 10A, 250V/500V MAX
(2500 mm)
Plug:
EL 212
(SI-32)
186574
Connector:
EL 701B
(IEC60320/C13)
EL-212
16A
250V
CAB-9K10A-IT Power Cord, 250VAC 10A CEI
23-16/VII Plug, Italy
Plug:
I/3G
(CEI 23-16)
Connector
C15M
(EN60320/C15 )
Cordset rating: 10 A, 250 V
Length: 8 ft 2 in. (2.5 m)
186575
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
Plug:
MP232-R
Cordset rating: 10 A, 250 V
Length: 8 ft. 2 in (2.5 m)
186578
Connector:
IEC 60320 C15
Table 14 Available Power Cords
Product ID (PID) PID Description Images
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
44
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Plug:
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
186580
Connector:
EL 701C
(EN 60320/C15)
EL 210
(BS 1363A) 13 AMP fuse
CAB-9K12A-NA
1
Power Cord, 125VAC 13A NEMA
5-15 Plug, North America
CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil
CAB-C13-C14-2M-JP Power Cord C13-C14, 2M/6.5ft
Japan PSE mark
Image not available
CAB-9K10A-KOR
1
Power Cord, 125VAC 13A KSC8305
Plug, Korea
Image not available
CAB-ACTW AC Power Cord (Taiwan), C13, EL
3
02, 2.3M
Image Not available
CAB-JPN-3PIN Japan, 90-125VAC 12A NEMA 5-15
Plug, 2.4m
Image Not available
CAB-48DC-40A-INT -48VDC PSU PWR Cord, 3.5M, 3
W
ire, 8AWG, 40A (INT)
Image Not available
CAB-48DC-40A-AS -48VDC PSU PWR Cord, 3.5M,
3W
ire, 8AWG, 40A (AS/NZ)
Image Not available
CAB-C13-C14-IN Power Cord Jumper,C13-C14
Connectors,1.4 M
eter Length, India
Image Not available
CAB-C13-C14-3M-IN Power Cord Jumper, C13-C14
Connectors, 3
Meter Length, India
Image Not available
Notes:
1. This power cord is rated to 125V and only supported for PSU rated at 1050W or less
Table 14 Available Power Cords
Product ID (PID) PID Description Images
1
76.2 From Plug End
2,133.6 ± 25
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
45
System Speed
STEP 11 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE
MANAGEMENT ARM
Select a Tool-less Rail Kit
Select a tool-less rail kit from Ta b l e 15.
Table 15 Tool-less Rail Kit Options
Product ID (PID) PID Description
UCSC-RAILF-M4 Friction Rail Kit for C220 M4 and C220 M5 Servers
UCSC-RAILB-M4 Ball Bearing Rail Kit for C220 and C240 M4/M5 Rack Servers
Select an Optional Reversible Cable Management Arm
The reversible cable management arm mounts on either the right or left slide rails at the rear of
the server and is used for cable management. Use Tab l e 16 to order a cable management arm.
Table 16 Cable Management Arm
Product ID (PID) PID Description
UCSC-CMAF-M4 Reversible CMA for C220 M4 and M5 rack servers
For more information about the tool-less rail kit and cable management ar
m, see the Cisco UCS
C220 M5 Installation and Service Guide at this URL:
https://www.cisco.com/c/en/us/td/docs/unified_
computing/ucs/c/hw/C220M5/install/C220M
5.html
NOTE: If you plan to rackmount your UCS C220 M5 server, you must order a tool-less
rail kit.The same rail kits and CMAs are used for M4 and M5 servers.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
46
STEP 12 SELECT MANAGEMENT CONFIGURATION (OPTIONAL)
By default, the C220 M5 server NIC mode is configured to be Shared LOM Extended. This NIC
mode allows any LOM port or adapter card port to be used to access the Cisco Integrated
Management Controller (CIMC). The Cisco VIC card must be installed in a slot with NCSI support.
To change the default NIC mode to Dedicated, select the UCSC-DLO
M-01 PID shown in Tab l e 17.
In Dedicated NIC mode, the CIMC can be accessed only through the dedicated managem
ent port.
See Chassis Rear View, page 6 for the location of the managem
ent port.
To change the default NIC mode to
Cisco Card Mode, select the UCSC-CCARD-01 PID shown in
Ta b l e 17. In this mode, you can assign an IP address to the CIMC
using DHCP and from there you
can fully automate your deployment.
For more details on all the NIC mode settings, see
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C480M5/install/C480M5/C480M5_c
hapter_010.html#concept_rqj_vsr_fz
Tab l e 17 Management Configuration Ordering Information
Product ID (PID) PID Description
UCSC-DLOM-01 Dedicated Mode BIOS setting for C-Series Servers
UCSC-CCARD-01 Cisco Card Mode BIOS setting for C-Series
Servers
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
47
System Speed
STEP 13 SELECT SERVER BOOT MODE (OPTIONAL)
By default, the C220 M5 server ships with UEFI as the default boot mode. To have a server
shipped with the Legacy BIOS mode (which was standard on M4 and previous generation servers),
select the Legacy BIOS PID from Tab l e 18.
Tab l e 18
Server Boot Mode Ordering Information
Product ID (PID) PID Description
UCSC-LBIOS-01 Legacy Boot Mode BIOS setting for C-Series Servers
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
48
STEP 14 ORDER SECURITY DEVICES (OPTIONAL)
A Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store
artifacts used to authenticate the platform (server). These artifacts can include passwords,
certificates, or encryption keys. A TPM can also be used to store platform measurements that
help ensure that the platform remains trustworthy. Authentication (ensuring that the platform
can prove that it is what it claims to be) and attestation (a process helping to prove that a
platform is trustworthy and has not been breached) are necessary steps to ensure safer
computing in all environments.
A chassis intrusion switch gives a notification of any unauthoriz
ed mechanical access into the
server.
The security device ordering information is listed in Ta b le 19
Tab l e 19 S ec u r i ty D ev i ce s
Product ID (PID) PID Description
UCSX-TPM2-001 Trusted Platform Module 1.2 SPI-based for UCS Servers
UCSX-TPM2-002 Trusted Platform Module 2.0 for UCS servers
UCSX-TPM2-002B Trusted Platform Module 2.0 M5 UCS Servers
(FIPS 140-2 Compliant)
UCSC-INT-SW01 C220 M5 and C240 M5 Chassis Intrusion Switch
.
NOTE:
The TPM module used in this system conforms to TPM v1.2 and 2.0, as defined
by the Trusted Computing Group (TCG). It is also SPI-based.
TPM installation is supported after-factory. However, a TPM installs with a
one-way screw and cannot be replaced, upgraded, or moved to another server. If
a server with a TPM is returned, the replacement server must be ordered with a
new TPM.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
49
System Speed
STEP 15 SELECT LOCKING SECURITY BEZEL (OPTIONAL)
An optional locking bezel can be mounted to the front of the chassis to prevent unauthorized
access to the drives.
Select the locking bezel from Ta bl e 20.
Table 20 Locking Bezel Option
Product ID (PID) Description
UCSC-BZL-C220M5 C220 M5 Security Bezel
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
50
STEP 16 ORDER CISCO SD CARD MODULE (OPTIONAL)
Order one or two matching SD cards. See Figure 5 on page 67 for the location of the mini
storage module connector, which accommodates an SD module. Each SD mo
dule accommodates
two SD cards.
Table 21 Secure Digital (SD) Card
Product ID (PID) PID Description
UCS-SD-128G 128 GB SD Card for UCS Servers
UCS-SD-64G-S 64 GB SD Card for UCS Servers
UCS-SD-32G-S 32 GB SD Card for UCS Servers
NOTE: Starti
ng from vSphere 8.0, SD cards/USB media as a standalone boot device
will not be supported by VMware. For more information please refer to the VMware
KB article: https://kb.vmware.com/s/article/85685
Caveats
Install either one or two SD cards
Do not mix SD card sizes
You cannot mix SD cards with an internal M.2 SATA SSD (see ORDER M.2 SATA SSDs
(OPTIONAL), page 51).
0
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
51
System Speed
STEP 17 ORDER M.2 SATA SSDs (OPTIONAL)
Order one or two matching M.2 SATA SSDs (see Ta b l e 22) along with a mini storage carrier or a
boot-optimized RAID controller (see Ta b l e 23).
NOTE: It is recommended that M.2 SATA SSDs be used as boot-only devices.
Each mini storage carrier or boot-optimized RAID controller can accommodate up to two SATA
M.2 SSDs shown in Ta b l e 22.
Table 22 M.2 SATA SSDs
Product ID (PID) PID Description
UCS-M2-I240GB 240GB SATA M.2 SSD
UCS-M2-I480GB 480GB SATA M.2 SSD
UCS-M2-240G 240GB SATA M.2
UCS-M2-480G 480GB M.2 SATA SSD
UCS-M2-960G 960GB SATA M.2
Table 23 Mini Storage Carrier/Boot-Optimized RAID Controller
Product ID (PID) PID Description
UCS-MSTOR-M2 Mini Storage Carrier for M.2 SATA (holds up to
2 M.2 SATA SSDs)
UCS-M2-HWRAID Cisco Boot optimized M.2 RAID controller (holds up to 2 M.2 SATA SSDs)
NOTE:
The UCS-M2-HWRAID boot-optimized RAID controller supports RAID 1 and JBOD mode
(CIMC/UCSM) is supported for configuring of volumes and monitoring of the controller
and installed SATA M.2 drives
The minimum version of Cisco IMC and Cisco UCS Manager that support this controller
is 4.0(4b) and later. The name of the controller in the software is MSTOR-RAID
The SATA M.2 drives can boot in UEFI mode only. Legacy boot mode is not supported
Hot-plug replacement is not supported. The server must be powered off.
The boot-optimized RAID controller is not supported when the server is used as a
compute node in HyperFlex configurations
Order either the Mini Storage carrier or the Boot-Optimized RAID controller from Ta b l e 23.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
52
Choose the UCS-MSTOR-M2 mini storage carrier for controlling the M.2 SATA drives
with no RAID control.
Choose the UCS-M2-HWRAID Boot-Optimized RAID controller for hardware RAID
across the two internal SA
TA M.2 drives. The Boot-Optimized RAID controller holds
up to 2 matching M.2 SATA drives.
Order up to two matching M.2 SATA SSDs from Ta b l e 22.
NOTE: The Boot-Optimized RAID controller supports VMWare, Windows and Linux
Operating Systems
Caveats
You cannot mix M.2 SATA SSDs with SD cards.
Order either one or two identical M.2 SATA SSDs for the mini-storage carrier or
boot-optimized RAID controller. You cannot mix M.2 SATA SSD capacities.
When ordering two M.2 SATA drives with embedded software RAID, the maximum number of
internal SATA drives supported is six. To support greater than six internal drives, a Cisco 12G
Raid Controller or a Cisco 12G SAS HBA must be ordered
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
53
System Speed
STEP 18 ORDER INTERNAL MICRO-SD CARD MODULE (OPTIONAL)
Order a 32 GB micro-SD card. The micro-SD card serves as a dedicated local resource for utilities
such as a Host Upgrade Utility (HUU). Images can be pulled from a file share (NFS/CIFS) and
uploaded to the card for future use.
Table 24 32 GB Secure Digital (SD) Card (blank)
Product ID (PID) PID Description
UCS-MSD-32G 32GB Micro-SD Card for UCS servers
Caveats
The micro-SD card mounts internally on riser 1.
The Flexutil user partition does not support OS installation. The user partition must be used
for storage only.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
54
STEP 19 ORDER OPTIONAL USB 3.0 DRIVE
You can order one optional USB 3.0 drive. The USB drive ordering information is listed in
Ta b l e 25
Table 25 USB 3.0 Drive
Product ID (PID) PID Description
UCS-USBFLSHB-16GB UCS Servers 16 GB Flash USB Drive
.
See Figure 5 on page 67 for the location of the USB connector.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
55
System Speed
STEP 20 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE
For more details on supported operating systems and software for this server, see the Hardware
and Software Compatibility List (HCL).
Note:
PIDs tagged with an asterisk (*) are Resell of an OEM Vendor’s Support. They are required
to be added to the associated Product License PID.Select
NOTE: VMware is on Compliance Hold. Contact the [email protected]
mailer to see if you are allowed to receive VMware Licenses
Cisco Software (Tab l e 26)
OEM Software (Ta b l e 27)
Operating System (Tab l e 28)
Tab l e 26 C isc o Sof t wa r e
Product ID (PID) PID Description
IMC Supervisor
CIMC-SUP-BASE-K9 IMC Supervisor One-time Site Installation License
CIMC-SUP-B01 IMC Supervisor-Branch Mgt SW for C-Series
& E-Series up to 100 Svrs
CIMC-SUP-B02 IMC Supervisor- Branch Mgt SW for C and
E-Series up to 250 Svrs
CIMC-SUP-B10 IMC Supervisor- Branch Mgt SW for C and
E-Series up to 1K Svrs
CIMC-SUP-B25 IMC Supervisor Branch Mgt SW for C and E-Series 25 Svrs
CIMC-SUP-A01 IMC Supervisor Adv-Branch Mgt SW for C and E-Se
ries 100 Svrs
CIMC-SUP-A02 IMC Supervisor Adv-Branch Mgt SW for C and E-Se
ries 250 Svrs
CIMC-SUP-A10 IMC Supervisor Adv-Branch Mgt SW for C and E-Se
ries 1000 Svrs
CIMC-SUP-A25 IMC Supervisor Adv-Branch Mgt SW for C and E-Series 25 Svrs
EVAL-CIMC-SUP-BAS EVAL: IMC Supervisor One-time Site Installation License
EVAL-CIMC-SUP EVAL: IMC Supervisor-Branch Mgt SW for C/E-Series - 50 Svrs
UCS Multi-Domain Manager
UCS-MDMGR-1S UCS Central Per Server License
NOTE: IF you must order quantity greater
than 1 of UCS-MDMGR-1S, you need to reference the UCS
Central Per Server Data Sheet to order the standalone PIDs: UCS-MDMGR-LIC= or UCS-MDMGR-1DMN=
Tab l e 27 OEM Software
Product ID (PID) PID Description
VMware vCenter
VMW-VCS-STD-1A VMware vCenter 7 Server Standard, 1 yr support require
VMW-VCS-STD-3A VMware vCenter 7 Server Standard, 3 yr support required
VMW-VCS-STD-5A VMware vCenter 7 Server Standard, 5 yr support required
VMW-VCS-FND-1A VMware vCenter 7 Server Foundation (4 Host), 1 yr supp reqd
VMW-VCS-FND-3A VMware vCenter 7 Server Foundation (4 Host), 3 yr supp reqd
VMW-VCS-FND-5A VMware vCenter 7 Server Foundation (4 Host), 5 yr supp reqd
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
56
Tab l e 28 Operating System
Product ID (PID) PID Description
Microsoft Windows Server
MSWS-19-DC16C Windows Server 2019 Data Center (16
Cores/Unlimited VMs)
MSWS-19-DC16C-NS Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC
MSWS-19-ST16C Windows Server 2019 Standard (16 Cores/2 VMs)
MSWS-19-ST16C-NS Windows Server 2019 Standard (16
Cores/2 VMs) - No Cisco SVC
MSWS-22-ST16C Windows Server 2022 Standard (16 Cores/2 VMs)
MSWS-22-ST16C-NS Windows Server 2022 Standard (16
Cores/2 VMs) - No Cisco SVC
MSWS-22-DC16C Windows Server 2022 Data Center (16
Cores/Unlimited VMs)
MSWS-22-DC16C-NS Windows Server 2022 DC (16 Cores/Unlim VMs) - No Cisco SVC
Red Hat
RHEL-2S2V-1A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req
RHEL-2S2V-3A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req
RHEL-2S2V-5A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req
RHEL-VDC-2SUV-1A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr Supp Req
RHEL-VDC-2SUV-3A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr Supp Req
RHEL-VDC-2SUV-5A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 5 Yr Supp Req
Red Hat Ent Linux/ High Avail/ Res Strg/ Scal
RHEL-2S2V-1S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1-Yr SnS
RHEL-2S2V-3S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3-Yr SnS
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
57
System Speed
RHEL-2S-HA-1S RHEL High Availability (1-2 CPU); Premium 1-yr SnS
RHEL-2S-HA-3S RHEL High Availability (1-2 CPU); Premium 3-yr SnS
RHEL-2S-RS-1S RHEL Resilent Storage (1-2 CPU); Premium 1-yr SnS
RHEL-2S-RS-3S RHEL Resilent Storage (1-2 CPU); Premium 3-yr SnS
RHEL-VDC-2SUV-1S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr SnS Reqd
RHEL-VDC-2SUV-3S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr SnS Reqd
Red Hat SAP
RHEL-SAP-2S2V-1S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS Reqd
RHEL-SAP-2S2V-3S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS Reqd
RHEL-SAPSP-3S RHEL SAP Solutions Premium - License with 3 Years of SnS
RHEL-SAPSS-3S RHEL SAP Solutions Standard - License with 3 Years of SnS
VMware
VMW-VSP-STD-1A VMware vSphere 7 Std (1 CPU, 32 Core) 1-yr, Support Required
VMW-VSP-STD-3A VMware vSphere 7 Std (1 CPU, 32 Core) 3-yr, Support Required
VMW-VSP-STD-5A VMware vSphere 7 Std (1 CPU, 32 Core) 5-yr, Support Required
VMW-VSP-EPL-1A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 1Yr, Support Reqd
VMW-VSP-EPL-3A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 3Yr, Support Reqd
VMW-VSP-EPL-5A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 5Yr, Support Reqd
SUSE
SLES-2S2V-1A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req
SLES-2S2V-3A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req
SLES-2S2V-5A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req
SLES-2S2V-1S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS
SLES-2SUV-3S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 3-Yr SnS
SLES-2SUV-5S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 5-Yr SnS
SLES-2S-HA-1S SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS
SLES-2S-HA-3S SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS
SLES-2S-HA-5S SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS
SLES-2S-GC-1S SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns
Tab l e 28 (continued)Operating System
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
58
SLES-2S-GC-3S SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS
SLES-2S-GC-5S SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS
SLES-2S-LP-1S SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required
SLES-2S-LP-3S SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required
SLES-2S-LP-1A SUSE Linux Live Patching Add-on (1-2 CPU); 1yr Support Req
SLES-2S-LP-3A SUSE Linux Live Patching Add-on (1-2 CPU); 3yr Support Req
SLES and SAP
SLES-SAP-2S2V-1A SLES for SAP Apps (1-2 CPU, 1-2 VM); 1-Yr Support Reqd
SLES-SAP-2S2V-3A SLES for SAP Apps (1-2 CPU, 1-2 VM); 3-Yr Support Reqd
SLES-SAP-2S2V-5A SLES for SAP Apps (1-2 CPU, 1-2 VM); 5-Yr Support Reqd
SLES-SAP-2S2V-1S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS
SLES-SAP-2S2V-3S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS
SLES-SAP-2S2V-5S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS
Tab l e 28 (continued)Operating System
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
59
System Speed
STEP 21 SELECT OPERATING SYSTEM MEDIA KIT
Select the optional operating system media listed in Ta b l e 29.
Tab l e 29 O S M e d ia
Product ID (PID) PID Description
MSWS-19-ST16C-RM Windows Server 2019 Stan (16 Cores/2 VMs) R
ec Media DVD Only
MSWS-19-DC16C-RM Windows Server 2019 DC (16Cores/Unlim VM) R
ec Media DVD Only
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
60
STEP 22 SELECT SERVICE and SUPPORT LEVEL
A variety of service options are available, as described in this section.
Unified Computing Warranty, No Contract
If you have noncritical implementations and choose to have no service contract, the following
coverage is supplied:
Three-year parts coverage.
Next business day (NBD) parts replacement eight hours a day, five days a week.
90-day software warranty on media.
Downloads of BIOS, drivers, and firmware updates.
UCSM updates for systems with Unified Computing System Manager. These updates include
minor enhancements and bug fixes that are designed to maintain the compliance of UCSM
with published specifications, release notes, and industry standards.
Smart Net Total Care (SNTC) for UCS
For support of the entire Unified Computing System, Cisco offers the Cisco Smart Net Total Care
for UCS
Service. This service provides expert software and hardware support to help sustain
performance and high availability of the unified computing environment. Access to Cisco
Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world
For systems that include Unified Computing System Manager, the support service includes
downloads of UCSM upgrades. The Cisco Smart Net Total Care for UCS Service
includes flexible
hardware replacement options, including replacement in as little as two hours.
There is also
access to Cisco's extensive online technical resources to help maintain optimal
efficiency and
uptime of the unified computing environment. For more information please refer to the following
url:
http://www.cisco.com/c/en/us/services/technical/smart-net-total-care.html?stickynav=1
You can choose a desired service
listed in Ta b l e 30.
Table 30 Cisco SNTC for UCS Service (PID UCSC-C220-M5SX)
Service SKU Service Level GSP On Site? Description
CON-PREM-C220M5SX C2P
Yes
SNTC 24X7X2OS
CON-UCSD8-C220M5SX UCSD8
Yes
UC SUPP DR 24X7X2OS*
CON-C2PL-C220M5SX C2PL
Yes
LL 24X7X2OS**
CON-OSP-C220M5SX C4P
Yes
SNTC 24X7X4OS
CON-UCSD7-C220M5SX UCSD7
Yes
UCS DR 24X7X4OS*
CON-C4PL-C220M5SX C4PL
Yes
LL 24X7X4OS**
CON-USD7L-C220M5SX USD7L
Yes
LLUCS HW DR 24X7X4OS***
CON-OSE-C220M5SX C4S
Yes
SNTC 8X5X4OS
CON-UCSD6-C220M5SX UCSD6
Yes
UC SUPP DR 8X5X4OS*
CON-SNCO-C220M5SX SNCO
Yes
SNTC 8x7xNCDOS****
CON-OS-C220M5SX CS
Yes
SNTC 8X5XNBDOS
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
61
System Speed
Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service
An enhanced offer over traditional Smart Net Total Care which provides onsite-troubleshooting
expertise to aid in the diagnostics
and isolation of hardware issue within our customers’ Cisco
Unified Computing System (UCS) environment. It is
delivered by a Cisco Certified field engineer
(FE) in collaboration with remote TAC engineer and
Virtual Internet working Support Engineer
(VISE). You can choose a desired service listed in
Tab l e 31 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSC-C220-M5SX)
Service SKU Service Level GSP On Site? Description
Note: For PID UCSC-C220-M5SN, select Service SKU with C220M5SN suffix (Example:CON-OSPT-C220M5SN)
*Includes Drive Retention (see UCS Drive Retention Service, page 65)
**Includes Local Language Support (see Local Language Technical Support for UCS, page 66) – Only
available in China and Japan
***Includes Local Language Support and Drive Retention – Only available in China and Japan
Ta b l e 31
CON-UCSD5-C220M5SX UCSD5
Yes
UCS DR 8X5XNBDOS*
CON-
S2P-C220M5SX S2P
No
SNTC 24X7X2
CON-
S2PL-C220M5SX S2PL
No
LL 24X7X2**
CON-
SNTP-C220M5SX SNTP
No
SNTC 24X7X4
CON-
SNTPL-C220M5SX SNTPL
No
LL 24X7X4**
CON-
SNTE-C220M5SX SNTE
No
SNTC 8X5X4
CON-SNC-C
220M5SX SNC
No
SNTC 8x7xNCD****
CON-SNT-C220M5SX
SNT
No
SNTC 8X5XNBD
CON
-SW-C220M5SX SW
No
SNTC NO RMA
Note: For PID UCSC-C220-M5SN, select a Service SKU with a C220M5SN suffix (Example: CON-PREM-C220M5SN)
*Includes Drive Retention (see UCS Drive Retention Service, page 65)
**Includes Local Language Support (see Local Language Technical Support for UCS, page 66) – Only
available in China and Japan
***Includes Local Language Support and Drive Retention – Only available in China and Japan
****Available in China Only
CON-OSPT-C220M5SX OSPT Yes 24X7X4OS Trblshtg
CON-OSPTD-C220M5S OSPTD Yes 24X7X4OS TrblshtgDR*
CON-OSPTL-C220M5SX OSPTL Yes 24X7X4OS TrblshtgLL**
CON-OPTLD-C220M5S OPTLD Yes 24X7X4OS TrblshtgLLD***
Table 30 Cisco SNTC for UCS Service (PID UCSC-C220-M5SX)
Service SKU Service Level GSP On Site? Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
62
Solution Support for UCS
Solution Support includes both Cisco product support and solution-level support, resolving
complex issues in multi-vendor environments, on average, 43% more quickly than product
support alone. Solution Support is a critical element in
data center administration, to help
rapidly resolve any issue encountered, while maintaining performance, reliability, and return on
investment.
This service centralizes support across your multi-vendor Cisco environment for both our
products and solution partner products
you’ve deployed in your ecosystem. Whether there is an
is
sue with a Cisco or solution partner product, just call us. Our experts are the primary point of
contact and own the case from first call to resolution. For more information please refer to the
fo
llowing url:
http://www.cisco.com/c/en/us/services/technical/so
lution-support.html?stickynav=1
You can choose a desired service
listed in Table 32.
Table 32 Solution Support for UCS
Service (PID UCSC-C220-M5SX)
Service SKU Service Level GSP On Site? Description
Note:For PID UCSC-C220-M5SN,select Service SKU with C220M5SN suffix (Example:CON-SSC2P-C220M5SN)
*Includes Drive Retention (see UCS Drive Retention Service, page 65)
**Available in China only
Smart Net Total Care for UCS Hardware Only Service
For faster parts replacement than is provided with the standard Cisco Unified Computing System
warranty, Cisco offers the Cisco Smart Net Total Care for UCS Hardware Only Service. You can
choose from two levels of advanced onsite parts replacement coverage in as little as four hours.
Smart Net Total Care for UCS Hardware Only Service provides remote access any time to Cisco
CON-SSC2P-C220M5SX SSC2P Yes SOLN SUPP 24X7X2OS
CON-SSC4P-C220M5SX SSC4P Yes SOLN SUPP 24X7X4OS
CON-SSC4S-C220M5SX SSC4S Yes SOLN SUPP 8X5X4OS
CON-SSCS-C220M5SX SSCS Yes SOLN SUPP 8X5XNBDOS
CON-SSDR7-C220M5SX SSDR7 Yes SSPT DR 24X7X4OS*
CON-SSDR5-C220M5SX SSDR5 Yes SSPT DR 8X5XNBDOS*
CON-SSS2P-C220M5SX SSS2P No SOLN SUPP 24X7X2
CON-SSSNP-C220M5SX SSSNP No SOLN SUPP 24X7X4
CON-SSSNE-C220M5SX SSSNE No SOLN SUPP 8X5X4
CON-SSSNC-C220M5SX SSSNC No SOLN SUPP NCD**
CON-SSSNT-C220M5SX SSSNT No SOLN SUPP 8X5XNBD
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
63
System Speed
support professionals who can determine if a return materials authorization (RMA) is required.
You can choose a desired service listed in
Table 33 SNTC for UCS Hardware Only Service (PID UCSC-C220-M5SX)
Service SKU Service Level GSP On Site? Description
CON-UCW7-C220M5SX UCW7 Yes UCS HW 24X7X4OS
CON-UCWD7-C220M5SX UCWD7 Yes UCS HW+DR 24X7X4OS*
CON-UCW7L-C220M5SX UCW7L Yes LL UCS 24X7X4OS**
CON-UWD7L-C220M5SX UWD7L Yes LL UCS DR 24X7X4OS***
CON-UCW5-C220M5SX UCW5 Yes UCS HW 8X5XNBDOS
CON-UCWD5-C220M5SX UCWD5 Yes
UCS HW+DR 8X5XNBDOS*
Note: For PID UCSC-C220-M5SN, select Service SKU with C220M5SN suffix (Example: CON-UCW7-C220M5SN)
*Includes Drive Retention (see UCS Drive Retention Service, page 65)
**Includes Local Language Support (see Local Language Technical Support for UCS, page 66) – Only
available in China and Japan
***Includes Local Language Support and Drive Retention – Only available in China and Japan
Tab l e 33
Partner Support Service for UCS
Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is
designed for partners to deliver their own branded support and managed services to enterprise
customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets
to help them:
Expand their service portfolios to support the most complex network environments
Lower delivery costs
Deliver services that increase customer loyalty
PSS options enable eligible Cisco partners to
develop and consistently deliver high-value
technical support that capitalizes on Cisco intellectual assets. This helps partners to realize
higher margins and expand their practice.
PSS is available to all Cisco PSS partners.
The two Partner Unified Computing Support Options include:
Partner Support Service for UCS
Partner Support Service for UCS Hardware Only
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
64
PSS for UCS provides hardware and software support, including triage support for third party
software, backed by Cisco technical resources and level three support.You can choose a desired
service listed in Ta b l e 34.
Table 34 PSS for UCS (PID UCSC-C220-M5SX)
Service SKU Service Level GSP On Site? Description
CON-PSJ8-C220M5SX PSJ8 Yes UCS PSS 24X7X2 OS
CON-PSJ7-C220M5SX PSJ7 Yes UCS PSS 24X7X4 OS
CON-PSJD7-C220M5SX PSJD7 Yes UCS PSS 24X7X4 DR*
CON-PSJ6-C220M5SX PSJ6 Yes UCS PSS 8X5X4 OS
CON-PSJD6-C220M5SX PSJD6 Yes UCS PSS 8X5X4 DR*
CON-PSJ4-C220M5SX PSJ4 No UCS SUPP PSS 24X7X2
CON-PSJ3-C220M5SX PSJ3 No UCS SUPP PSS 24X7X4
CON-PSJ2-C220M5SX PSJ2 No UCS SUPP PSS 8X5X4
CON-PSJ1-C220M5SX PSJ1 No
UCS SUPP PSS 8X5XNBD
Note: For PID UCSC-C220-M5SN, select Service SKU with C220M5SN suffix (Example: CON-PSJ1-C220M5SN)
*Includes Drive Retention (see UCS Drive Retention Service, page 65)
PSS for UCS Hardware Only
PSS for UCS Hardware Only provides customers with replacement parts in as little as two hours
and provides remote access any time to Partner Support professionals who can determine if a
return materials authorization (RMA) is required. You can choose a desired service listed in
Table 35 PSS for UCS Hardware Only (PID UCSC-C220-M5SX)
Service SKU Service Level GSP On Site? Description
CON-PSW7-C220M5SX PSW7 Ye s UCS W PSS 24X7X4 OS
CON-PSWD7-C220M5SX PSWD7 Ye s UCS W PSS 24X7X4 DR*
CON-PSW6-C220M5SX PSW6 Ye s UCS W PSS 8X5X4 OS
CON-PSWD6-C220M5SX PSWD6 Ye s UCS W PSS 8X5X4 DR*
CON-PSW4-C220M5SX PSW4 No UCS W PL PSS 24X7X2
CON-PSW3-C220M5SX PSW3 No UCS W PL PSS 24X7X4
CON-PSW2-C220M5SX PSW2 No
UCS W PL PSS 8X5X4
Note: For PID UCSC-C220-M5SN, select Service SKU with C220M5SN suffix (Example: CON-PSW2-C220M5SN)
*Includes Drive Retention (see UCS Drive Retention Service, page 65)
Table 35
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
65
System Speed
Unified Computing Combined Support Service
Combined Services makes it easier to purchase and manage required services under one
contract. SNTC services for UCS help increase the availability of your vital data center
infrastructure and realize the most value from your unified computing investment. The more
benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important
the technology becomes to your business. These services allow you to:
Optimize the uptime, performance, and efficiency of your UCS
Protect your vital business applications by rapidly identifying and addressing issues
Strengthen in-house expertise through knowledge transfer and mentoring
Improve operational efficiency by allowing UCS experts to augment your internal staff
resources
Enhance business agility by diagnosing potential issues before they affect your operations,
You can choose a desired service listed in
Table 36 Combined Support Service for UCS (PID UCSC-C220-M5SX)
Service SKU Service Level GSP On Site? Description
CON-NCF2P-C220M5SX NCF2P Yes CMB SVC 24X7X2OS
CON-NCF4P-C220M5SX NCF4P Yes CMB SVC 24X7X4OS
CON-NCF4S-C220M5SX NCF4S Yes CMB SVC 8X5X4OS
CON-NCFCS-C220M5SX NCFCS Yes CMB SVC 8X5XNBDOS
CON-NCF2-C220M5SX NCF2 No CMB SVC 24X7X2
CON-NCFP-C220M5SX NCFP No CMB SVC 24X7X4
CON-NCFE-C220M5SX NCFE No CMB SVC 8X5X4
CON-NCFT-C220M5SX NCFT No CMB SVC 8X5XNBD
CON-NCFW-C220M5SX NCFW No
CMB SVC SW
Note: For PID UCSC-C220-M5SN, select Service SKU with C220M5SN suffix (Example: CON-NCF2P-C220M5SN)
Table 36
UCS Drive Retention Service
With the Cisco Unified Computing Drive Retention Service, you can obtain a new disk drive in
exchange for a faulty drive without returning the faulty drive.
Sophisticated data recovery tec
hniques have made classified, proprietary, and confidential
information vulnerable, even on malfunctioning disk drives. The Drive Retention service enables
you to
retain your drives and ensures that the sensitive data on those drives is not compromised,
which
reduces the risk of any potential liabilities. This service also enables you to comply with
regulatory, local, and federal requirements.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
System Speed
66
If your company has a need to control confidential, classified, sensitive, or proprietary data, you
might want to consider one of the Drive Retention Services listed in the above tables (where
available)
NOTE: Cisco does not offer a certified drive destruction service as part of this
service.
Local Language Technical Support for UCS
Where available, and subject to an additional fee, local language support for calls on all
assigned severity levels may be available for specific product(s) – see tables above.
For a complete listing of available services for C
isco Unified Computing System, see the following
URL:
http://www.cisco.com/en/US/products/p
s10312/serv_group_home.html
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
67
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
Chassis
An internal view of the C220 M5 chassis with the top cover removed is shown in Figure 5.
Figure 5 C220 M5 SFF With Top Cover Off
1 For UCSC-C220-M5SX:
Drive bays 1–10 support SAS/SATA drives and
drive bays 1 and 2 also support SFF NVMe
PCIe SSDs. Two CPUs are required if NVMe
SSDs are implemented.
For UCSC-C220-M5SN:
Drive bays 1–10 support SFF NVMe PCIe SSDs
(only). Two CPUs are required.
9 Power supplies (Hot-swappable when
redundant as 1+1)
2 Cooling fan modules (seven) 10 Trusted platform module (TPM) socket on
motherboard (not visible in this view)
3 Supercap Power Module (RAID backup)
mounting bracket
11 PCIe slot 2 (half-height, x16); includes PCIe
cable connector for SFF NVMe SSDs (x8)
4 DIMM sockets on motherboard (12 per CPU;
24 total)
12 PCIe slot 1 (full-height, x16); includes
socket for Micro-SD card
5 CPUs and heatsinks (up to two) 13 Modular LOM (mLOM) card bay on chassis
floor (x16) (not visible in this view)
Fan 07
Fan 06
Fan 05
Fan 03
CPU 01
CPU 02
PSU 02
PSU 01
PCIe 02
PCIe 01
SCPM
Fan 02
Fan 01
Fan 04
10
11
12
305952
2 4
14
5 6 7 83
9
1
mRAID
13
16
15
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
68
6 Mini storage module connector
Supports either an SD card module with two
SD cards or an M.2 module with two
PCIe/SATA M.2 SSD slots
14 Modular RAID (mRAID) riser, which supports
any of the following:
Hardware RAID controller card
Interposer card for embedded SATA
RAID
PCIe switch card for SFF NVMe drives
in slots 3 through 10
(for
UCSC-C220-M5SN only)
7 Internal USB 3.0 port on motherboard 15 PCIe cable connectors for front-panel NVMe
SSDs on PCIe riser 2
8 RTC battery vertical socket on motherboard 16 Micro-SD card socket on PCIe riser 1
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
69
SUPPLEMENTAL MATERIAL
Block Diagram
Figure 6 C220 M5 SFF Block Diagram
h^ͲϮϮϬͲDϱ^͕ϭh
yϰ^^
ŽŶŶĞĐƚŽƌ
ϭ
Ϯ
^^džϰ
^^džϰ
ϯ
ϰ
ϱ
ϲ
ϳ
ϴ
yϰ^^
ŽŶŶĞĐƚŽƌ
h^ͲϮϰϬͲDϱ^E͕ϭh;EsDĞŽŶůLJĚƌŝǀĞƐͿ
^^džϰ
yϰ^^
ŽŶŶĞĐƚŽƌ
yϰ^d
ŽŶŶĞĐƚŽƌ
yϰ^d
ŽŶŶĞĐƚŽƌ
/ŶƚĞů
>ĞǁŝƐďƵƌŐW,
^d
^d
yϰ^d
ŽŶŶĞĐƚŽƌ
yϰ^d
ŽŶŶĞĐƚŽƌ
^d
^d
ŽŶŶĞĐƚŽƌĨŽƌDŽĚƵůĂƌZ/ĐĂƌĚ͕Žƌ,ĂƌĚ͕Žƌ
DͲƐǁŝƚĐŚĐĂƌĚ͕Žƌ^d/ŶƚĞƌƉŽƐĞƌĂƌĚ
ĂďůĞƐƚŽŵŽĚƵůĂƌ
Z/ͬ,ͬ^d
/ŶƚĞƌƉŽƐĞƌĐĂƌĚ
ϭ
ŚĂŶ
ŚĂŶ
ŚĂŶ
ŚĂŶ
/ŶƚĞů
yĞŽŶ
^ŬLJůĂŬĞW
;WhϭͿ
/ŶƚĞů
yĞŽŶ
^ŬLJůĂŬĞW
;WhϮͿ
W/ĞZŝƐĞƌϭ
D/ϯ
D/ϯ;džϰͿ
h^
dŚƵŵďĚƌŝǀĞ
h^ϯ͘ϬͬϮ͘Ϭ
s'
ϭϬ'Ͳd
ϭϬ'Ͳd
ϭ'Ͳd
;DŐŵƚͿ
^ĞƌŝĂů
W/Ğdžϭϲ'ĞŶϯ
ŵ>KD
DŽĚƵůĞ
;ĂǀĂƌŝĞƚLJŽĨ
ŶĞƚǁŽƌŬĐĂƌĚƐĐĂŶ
ďĞŝŶƐƚĂůůĞĚŚĞƌĞͿ
W/Ğdžϭϲ
'ĞŶϯƐůŽƚ
'ďƐǁŝƚĐŚ
ϮͲƉŽƌƚ
džϱϱϬE/
ĞDD
D
ZĞĂƌWĂŶĞů
EĞƚǁŽƌŬĐŽŶŶĞĐƚŽƌƐ
;ƚLJƉĞƐǀĂƌLJǁŝƚŚŵ>KDŵŽĚƵůĞͿ
͘͘͘͘͘͘͘͘͘͘͘͘
DŝŶŝ^ƚŽƌĂŐĞ
DŽĚƵůĞ
;^ͬD͘ϮͿ
ŝƐĐŽϮϰϬDϱϭh^ĞƌǀĞƌ^LJƐƚĞŵůŽĐŬŝĂŐƌĂŵ
h^ϯ͘Ϭ
&ƌŽŶƚWĂŶĞů
<sD
ŽŶŶĞĐƚŽƌ
yϮh^Ϯ͘Ϭ
ϭs'
ϭ^ĞƌŝĂů
Ϯ
ϭ Ϯ
ϭ Ϯ
ϭ Ϯ
ϭ Ϯ
ŚĂŶ
ŚĂŶ&
ŚĂŶ'
ŚĂŶ,
ŚĂŶ:
ŚĂŶ<
ŚĂŶ>
ŚĂŶD
hW/;ϯdžϭϬ͘ϰ'dͬƐͿ
yϰ^^
ŽŶŶĞĐƚŽƌ
ηϭ
ĂďůĞƚŽW/Ğ
ĐŽŶŶĞĐƚŽƌŽŶZŝƐĞƌϮ
ĨŽƌϮŽƉƚŝŽŶĂůĨƌŽŶƚ
EsDĞĚƌŝǀĞƐ
ĂďůĞƐƚŽ
DͲƐǁŝƚĐŚĐĂƌĚ
dĞŶĨƌŽŶƚĚƌŝǀĞƐ;Ϯ͘ϱΗͿ
;^^ͬ^d,ƐŽƌ^^Ɛ͕ŽƉƚŝŽŶĂůEsDĞĚƌŝǀĞƐ
yϰ^^
ŽŶŶĞĐƚŽƌ
ηϮ
yϰ^^
ŽŶŶĞĐƚŽƌ
ηϯ
ĂďůĞƐƚŽĚƌŝǀĞďĂĐŬƉůĂŶĞƐ
x &ŽƌϭϬͲĚƌŝǀĞƐLJƐƚĞŵ͕ƚŚƌĞĞdžϰ^^ĐŽŶŶĞĐƚŽƌƐĨŽƌϭϬĨƌŽŶƚ
^^ͬ^dĚƌŝǀĞƐ
x &ŽƌϰͲĚƌŝǀĞƐLJƐƚĞŵ͕ƚǁŽdžϰ^^ĐŽŶŶĞĐƚŽƌĨŽƌϰĨƌŽŶƚ
^^ͬ^dĚƌŝǀĞƐŽƌŽŶĞdžϰ^^ĐŽŶŶĞĐƚŽƌĨŽƌϮĨƌŽŶƚ
ĚƌŝǀĞƐ
x &ŽƌϭϬͲĚƌŝǀĞEsDĞŽŶůLJƐLJƐƚĞŵ͕ĨŽƵƌdžϴKĐƵůŝŶŬ
ĐŽŶŶĞĐƚŽƌƐĨŽƌϴEsDĞĚƌŝǀĞƐ
ĂďůĞƚŽW/Ğ
ĐŽŶŶĞĐƚŽƌŽŶZŝƐĞƌϮ
ĨŽƌϮĨƌŽŶƚEsDĞ
ĚƌŝǀĞƐ
ϭ
Ϯ
ϯ
ϰ
ϱ
ϲ
ϳ
ϴ
ϭϬĨƌŽŶƚĚƌŝǀĞƐ;Ϯ͘ϱΗͿ
EsDĞĚƌŝǀĞƐ
h^ͲϮϰϬͲDϱ>͕ϭh
ϭ
Ϯ
ϯ
ϰ
ĂďůĞƚŽW/Ğ
ĐŽŶŶĞĐƚŽƌŽŶZŝƐĞƌϮ
ĨŽƌϮŽƉƚŝŽŶĂůĨƌŽŶƚ
EsDĞĚƌŝǀĞƐ
ĂďůĞƐƚŽŵŽĚƵůĂƌ
Z/ͬ,ͬ^d
/ŶƚĞƌƉŽƐĞƌĐĂƌĚ
ϰĨƌŽŶƚĚƌŝǀĞƐ;ϯ͘ϱΗͿ
;^^ͬ^d,ƐŽƌ^^Ɛ͕ŽƉƚŝŽŶĂůEsDĞĚƌŝǀĞƐ
^ůŽƚϭ
P^ƐůŽƚ
^ůŽƚϮ
W/ĞZŝƐĞƌϮ
&ƌŽŶƚ
EsDĞŽŶŶ
h^ϯ͘Ϭ
W/Ğ;ϮdžϮͿĂŶĚ
Ɛ^d;džϮͿ
Zϰ/DDƐ
W/Ğͬ>W
W/Ğdžϭϲ'ĞŶϯ
W/ĞdžϮϰ'ĞŶϯ;džϭϲƚŽƌŝƐĞƌ͕džϴƚŽ&ƌŽŶƚEsDĞͿ
ϵ
ϭϬ
^^džϰ
yϰ^^
ŽŶŶĞĐƚŽƌ
yϴKĐƵůŝŶŬ
ŽŶŶĞĐƚŽƌ
ηϭ
yϴKĐƵůŝŶŬ
ŽŶŶĞĐƚŽƌ
ηϮ
yϴKĐƵůŝŶŬ
ŽŶŶĞĐƚŽƌ
ηϯ
yϴKĐƵůŝŶŬ
ŽŶŶĞĐƚŽƌ
ηϰ
ϵ
ϭϬ
yϴKĐƵůŝŶŬ
ŽŶŶĞĐƚŽƌ
yϴKĐƵůŝŶŬ
ŽŶŶĞĐƚŽƌ
yϴKĐƵůŝŶŬ
ŽŶŶĞĐƚŽƌ
yϴKĐƵůŝŶŬ
ŽŶŶĞĐƚŽƌ
džϰ
džϰ
džϰ
džϰ
džϰ
džϰ
džϰ
džϰ
D/ϯ
W/Ğdžϰ'ĞŶϯ
h^ϯ͘ϬͬϮ͘Ϭ
W/Ğdžϴ'ĞŶϯ
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
70
RAID Option ROM (OPROM) Settings
The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option
ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used
for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS
screen is shown in Figure 7.
Figure 7 Example BIOS Screen for OPROM
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
71
SUPPLEMENTAL MATERIAL
To Create a RAID Group
(1) While the server is booting, wait for the prompt and press function key F2 as shown in
Figure 8.
Figure 8 Function Key F2 Prompt
In a few seconds, you will see the screen that allows you to set up a RAID group for the primary
SATA controller (see Figure 9).
Figure 9 Screen to Configure Primary SATA RAID Group
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
72
(2) Press Ctrl+M to start the RAID group creation process for the primary SATA controller (for
drives 1-4, as shown in Figure 9 on page 71). Or, do nothing and wait for the next screen, which
allows you to create a RAID group for the secondary SATA (sSATA) controller see Figure 10).
Figure 10 Screen to Configure Secondary SATA (sSATA) RAID Group
(3) Press Ctrl+M to start the RAID group creation process for the secondary SATA (sSATA)
controller (for drives 5-8, as shown in Figure 7 on page 70).
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
73
SUPPLEMENTAL MATERIAL
Serial Port Details
The pinout details of the rear RJ-45 serial port connector are shown in Figure 11.
Figure 11 Serial Port (Femal
e RJ-45 Connector) Pinout
1
2
3
4
5
6
7
8
Pin
Serial Port (RJ-45 Female Connector)
Signal
RTS (Request to Send)
DTR (Data Terminal Ready)
TxD (Transmit Data)
RxD (Receive Data)
DSR (Data Set Ready)
CTS (Clear to Send)
GND (Signal Ground)
GND (Signal Ground)
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
74
KVM Cable
The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for
a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct
connection to the operating system and the BIOS running on the server.
The KVM cable ordering information is listed in Tab l e 37.
Table 37 KVM Cable
Product ID (PID) PID Description
N20-BKVM= KVM cable for UCS Server console port
Figure 12 KVM Cable
1 Connector (to server front panel) 3 VGA connector (for a monitor)
2 DB-9 serial connector 4 Two-port USB connector (for a mouse and keyboard)
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
75
SPARE PARTS
SPARE PARTS
This section lists the upgrade and service-related parts for the UCS C220 M5 server. Some of these parts are
configured with every server
.
Table 38 Spare Parts
Product ID (PID) PID Description
KVM Cable
N20-BKVM= KVM local IO cable for UCS servers console port
CPUs
UCS-CPU-I8280 Intel 8280 2.7GHz/205W 28C/38.50MB 3DX DDR4 2933 MHz
UCS-CPU-I8280L Intel 8280L 2.7GHz/205W 28C/38.50MB 3DX DDR4 4.5TB 2933 MHz
UCS-CPU-I8276 Intel 8276 2.2GHz/165W 28C/38.50MB 3DX DDR4 2933 MHz
UCS-CPU-I8276L Intel 8276L 2.2GHz/165W 28C/38.50MB 3DX DDR4 4.5TB 2933 MHz
UCS-CPU-I8270 Intel 8270 2.6GHz/205W 26C/35.75MB 3DX DDR4 2933 MHz
UCS-CPU-I8268 Intel 8268 2.9GHz/205W 24C/35.75MB 3DX DDR4 2933 MHz
UCS-CPU-I8260 Intel 8260 2.4GHz/165W 24C/35.75MB 3DX DDR4 2933 MHz
UCS-CPU-I8260Y Intel 8260Y SS 2.4GHz/165W 24/20/16C 35.75MB 3DX DDR4 2933
UCS-CPU-I8260L Intel 8260L 2.4GHz/165W 24C/35.75MB 3DX DDR4 4.5TB 2933 MHz
UCS-CPU-I8253 Intel 8253 2.2GHz/125W 16C/22MB DCP DDR4 1TB 2933 MHz
UCS-CPU-I6262V Intel 6262V 1.9GHz/135W 24C/33MB 3DX DDR42400MHz
UCS-CPU-I6258R Intel 6258R 2.7GHz/205W 28C/35.75MB DDR4 2933MHz
UCS-CPU-I6254 Intel 6254 3.1GHz/200W 18C/24.75MB 3DX DDR4 2933 MHz
UCS-CPU-I6252 Intel 6252 2.1GHz/150W 24C/35.75MB 3DX DDR4 2933 MHz
UCS-CPU-I6248 Intel 6248 2.5GHz/150W 20C/27.5MB 3DX DDR4 2933 MHz
UCS-CPU-I6248R Intel 6248R 3GHz/205W 24C/35.75MB DDR4 2933MHz
UCS-CPU-I6246 Intel 6246 3.3GHz/165W 12C/24.75MB 3DX DDR4 2TB 2933 MHz
UCS-CPU-I6246R Intel 6246R 3.4GHz/205W 16C/35.75MB DDR4 2933MHz
UCS-CPU-I6244 Intel 6244 3.6GHz/150W 8C/24.75MB 3DX DDR4 2933 MHz
UCS-CPU-I6242 Intel 6242 2.8GHz/150W 16C/22MB 3DX DDR4 2933 MHz
UCS-CPU-I6242R Intel 6242R 3.1GHz/205W 20C/35.75MB DDR4 2933MHz
UCS-CPU-I6240 Intel 6240 2.6GHz/150W 18C/24.75MB 3DX DDR4 2933 MHz
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
76
UCS-CPU-I6240R Intel 6240R 2.4GHz/165W 24C/35.75MB DDR4 2933MHz
UCS-CPU-I6240Y Intel 6240Y SS 2.6GHz/150W 18/14/8C 24.75MB 3DX DDR4 2933
UCS-CPU-I6240L Intel 6240L 2.6GHz/150W 18C/24.75MB 3DX DDR4 4.5TB 2933 MHz
UCS-CPU-I6238 Intel 6238 2.1GHz/140W 22C/30.25MB 3DX DDR4 2933 MHz
UCS-CPU-I6238R Intel 6238R 2.2GHz/165W 28C/38.5MB DDR4 2933MHz
UCS-CPU-I6238L Intel 6238L 2.1GHz/140W 22C/30.25MB 3DX DDR4 4.5TB 2933 MHz
UCS-CPU-I6234 Intel 62343.3GHz/130W 8C/24.75MB 3DX DDR4 2933 MHz
UCS-CPU-I6230 Intel 6230 2.1GHz/125W 20C/27.50MB 3DX DDR4 2933 MHz
UCS-CPU-I6230R Intel 6230R 2.1GHz/150W 26C/35.75MB DDR4 2933MHz
UCS-CPU-I6230N Intel 6230N 2.3GHz/125W 20C/27.50MB DCP DDR4 2933 MHz
UCS-CPU-I6226 Intel 62262.7GHz/125W 12C/19.25MB 3DX DDR4 2933 MHz
UCS-CPU-I6226R Intel 6226R 2.8GHz/150W 16C/22MB DDR4 2933MHz
UCS-CPU-I6222V Intel 6222V 1.8GHz/115W 20C/27.5MB 3DX DDR42400MHz
UCS-CPU-6146 3.2 GHz 6146/165W 12C/24.75MB Cache/DDR4 2666MHz
UCS-CPU-I5222 Intel 5222 3.8GHz/105W 4C/16.50MB 3DX DDR4 2933 MHz
UCS-CPU-I5220S Intel 5220S 2.6GHz/125W 18C/19.25MB 3DX DDR4 2665 MHz
UCS-CPU-I5220 Intel 5220 2.2GHz/125W 18C/19.25MB 3DX DDR4 2665 MHz
UCS-CPU-I5220R Intel 5220R 2.2GHz/125W 18C/24.75MB DCP DDR4 2666MHz
UCS-CPU-I5218B Intel 5218B 2.3GHz/125W 16C/22MB 3DX DDR4 2TB 2933 MHz
UCS-CPU-I5218 Intel 5218 2.3GHz/125W 16C/16.50MB 3DX DDR4 2666MHz
UCS-CPU-I5218R Intel 5218R 2.2GHz/125W 20C/27.5MB DDR4 2667MHz
UCS-CPU-I5218N Intel 5218N 2.3GHz/105W 16C/22MB DCP DDR4 2666MHz
UCS-CPU-I5217 Intel 5217 3.0GHz/85W 8C/16.50MB 3DX DDR4 2665 MHz
UCS-CPU-I5215 Intel 5215 2.5GHz/85W 10C/13.75MB 3DX DDR4 2666MHz
UCS-CPU-I5215L Intel 5215L 2.5GHz/85W 10C/13.75MB 3DX DDR4 4.5TB 2666MHz
UCS-CPU-I4216 Intel 4216 2.1GHz/100W 16C/16.50MB DDR4 2400MHz
UCS-CPU-I4215R Intel 4215R 3.2GHz/130W 10C/11MB DCP DDR4 1TB 2400 MHz
UCS-CPU-I4215 Intel 4215 2.5GHz/85W 8C/13.75MB 3DX/DDR4 2400MHz
UCS-CPU-I4214 Intel 4214 2.2GHz/85W 12C/13.75MB DDR4 2400MHz
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
77
SPARE PARTS
UCS-CPU-I4214R Intel 4214R 2.4GHz/100W 12C/16.50MB DDR4 2400MHz
UCS-CPU-I4210 Intel 4210 2.2GHz/85W 10C/11MB DDR4 2400MHz
UCS-CPU-I4210R Intel 4210R 2.4GHz/100W 10C/13.75MB DDR4 2400MHz
UCS-CPU-I4208 Intel 4208 2.1GHz/85W 8C/11MB DDR4 2400MHz
UCS-CPU-I3206R Intel 3206R 1.9GHz/85W 8C/11MB DDR4 2133MHz
CPU Accessories
UCSC-HS-C220M5= Heat sink for UCS C220 M5 rack servers 150W CPUs & below
UCSC-HS2-C220M5= Heat sink for UCS C220 M5 rack servers CPUs above 150W
UCS-CPU-TIM=
Single CPU thermal interface material syringe for M5 server HS seal
1
UCSX-HSCK=
UCS Processor Heat Sink Cleaning Kit (when replacing a CPU)
2
UCS-CPUAT= CPU Assembly Tool for M5 Servers
UCS-M5-CPU-CAR= UCS M5 CPU Carrier
UCSC-FAN-C220M5= C220 M5 Fan Module (one)
Riser
UCSC-RISER-220M5= PCIe Riser for C220 M5
SD Cards
UCS-MSTOR-SD= SD module (holds up to 2 SD cards)
M.2 SATA SSD and Raid controller
UCS-MSTOR-M2= M.2 module (holds up to 2 M.2 SATA drives)
UCS-M2-HWRAID = Cisco Boot optimized M.2 RAID controller (holds up to 2 M.2 SATA SSDs)
UCS-M2-I240GB= 240 GB M.2 SATA SSD
UCS-M2-I480GB= 480 GB M.2 SATA SSD
UCS-M2-240G= 240GB SATA M.2
UCS-M2-480G= 480GB M.2 SATA SSD
UCS-M2-960G= 960GB SATA M.2
Memory
UCS-ML-128G4RW= 128GB DDR4-3200MHz LRDIMM 4Rx4 (16Gb)
UCS-MR-X64G2RW= 64GB DDR4-3200MHz RDIMM 2Rx4 (16Gb)
UCS-MR-X32G2RW= 32GB DDR4-3200MHz RDIMM 2Rx4 (8Gb)
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
78
UCS-MR-X16G1RW= 16GB DDR4-3200MHz RDIMM 1Rx4 (8Gb)
UCSC-BBLKD-S2= C-Series M5 SFF drive blanking panel
DRIVES
HDDs
HDDs (15K RPM)
UCS-HD300G15K12N= 300 GB 12G SAS 15K RPM SFF HDD
UCS-HD600G15K12N= 600 GB 12G SAS 15K RPM SFF HDD
UCS-HD900G15K12N= 900 GB 12G SAS 15K RPM SFF HDD
HDDs (10K RPM)
UCS-HD300G10K12N= 300 GB 12G SAS 10K RPM SFF HDD
UCS-HD600G10K12N= 600 GB 12G SAS 10K RPM SFF HDD
UCS-HD12TB10K12N= 1.2 TB 12G SAS 10K RPM SFF HDD
UCS-HD18TB10K4KN= 1.8 TB 12G SAS 10K RPM SFF HDD (4K)
UCS-HD24TB10K4KN= 2.4 TB 12G SAS 10K RPM SFF HDD (4K)
HDDs (7.2K RPM)
UCS-HD1T7K12N= 1 TB 12G SAS 7.2K RPM SFF HDD
UCS-HD2T7K12N= 2 TB 12G SAS 7.2K RPM SFF HDD
UCS-HD1T7K6GAN= 1 TB 6G SATA 7.2K RPM SFF HDD
SAS/SATA SSDs
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per
day))
SAS SSDs
UCS-SD800GK3X-EP= 800GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
UCS-SD16TK3X-EP= 1.6TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
UCS-SD32TK3X-EP= 3.2TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
SATA SSDs
UCS-SD480G63X-EP= 480GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) (Intel
S4600/S4610)
UCS-SD960G63X-EP= 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) (Intel
S4600/S4610)
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
79
SPARE PARTS
UCS-SD19T63X-EP= 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance) (Intel
S4600/S4610)
UCS-SD19TBM3X-EP= 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance)
UCS-SD960GBM3X-EP= 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)
UCS-SD480GBM3X-EP= 480GB 2.5in Enterprise Performance 6GSATA SSD(3X endurance)
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))
SAS SSDs
UCS-SD960GK1X-EV= 960 GB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD19TK1X-EV= 1.9 TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD38TK1X-EV= 3.8 TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD76TK1X-EV= 7.6 TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD15TK1X-EV= 15.3 TB 2.5 inch Enterprise Value 12G SAS SSD
SATA SSDs
UCS-SD76TBM1X-EV= 7.6TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD38TBM1X-EV= 3.8TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD19TBM1X-EV= 1.9TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD16TBM1X-EV= 1.6TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD960GBM1X-EV= 960GB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD480GBM1X-EV= 480 GB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD240GBM1X-EV= 240GB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD120GM1X-EV= 120 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100
/5200/5300)
UCS-SD19T61X-EV= 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung
PM863A/PM883)
UCS-SD38T61X-EV= 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung
PM863A/PM883)
UCS-SD480G6I1X-EV= 480GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4510/5300)
UCS-SD960G6I1X-EV= 960GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4510)
UCS-SD38T6I1X-EV= 3.8TB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4510)
UCS-SD960G6S1X-EV= 960GB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD19T6S1X-EV= 1.9TB 2.5 inch Enterprise Value 6G SATA SSD
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
80
UCS-SD38T6S1X-EV= 3.8TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD76T6S1X-EV= 7.6TB 2.5 inch Enterprise Value 6G SATA SSD
SATA Interposer board
UCSC-SATAIN-220M5= C220 M5 (8-drive) SATA Interposer board
Self-Encrypted Drives (SED)
UCS-HD600G15NK9= 600 GB 12G SAS 15K RPM SFF HDD (SED) FIPS140-2
UCS-HD24T10NK9= 2.4 TB 12G SAS 10K RPM SFF HDD (4K) (SED) FIPS140-2
UCS-HD18T10NK9= 1.8 TB 12G SAS 10K RPM SFF HDD (4K format, SED) FIPS140-2
UCS-HD12T10NK9= 1.2 TB 12G SAS 10K RPM SFF HDD (SED) FIPS140-2
UCS-SD960GBKNK9= 960GB 2.5" Enterprise value 12G SAS SSD (1X endurance, FIPS)
UCS-SD38TBKNK9= 3.8TB 2.5" Enterprise value 12G SAS SSD (1DWPD, SED-FIPS)
UCS-SD800GBKNK9= 800GB 2.5" Enterprise performance 12GSAS SSD(3DWPD,SED-FIPS
UCS-SD16TBKNK9= 1.6TB 2.5" Enterprise performance 12GSAS SSD(3DWPD,SED-FIPS)
UCS-SD76TBKNK9= 7.6TB Enterprise value SAS SSD (1 DWPD, SED-FIPS) FIPS140-2
PCIe/NVMe SFF (2.5-inch) drives
UCSC-NVMEXPB-I375= Cisco 375GB 2.5in Intel Optane NVMe Extreme Performance SSD
UCSC-NVMEXP-I750= Cisco 750GB 2.5in Intel Optane NVMe Extreme Perf
UCS-NVME4-1920= 1.9TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe
UCS-NVME4-3840= 3.8TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe
UCS-NVME4-7680= 7.6TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe
UCS-NVME4-1536= 15.3TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe
UCS-NVME4-1600= 1.6TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X)
UCS-NVME4-3200= 3.2TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X)
UCS-NVME4-6400= 6.4TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X)
UCS-NVMEQ-1536= 15.3TB 2.5in U.2 15mm P5316 Hg Perf Low End NVMe
UCS-NVMEM6-W3200= 3.2TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance
UCS-NVMEM6-W7680= 7.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance
UCS-NVMEM6-W15300= 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance
Drive cables/accessories
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
81
SPARE PARTS
UCSC-BBLKD-S2= C-Series M5 SFF drive blanking panel
CBL-NVME-C220FF= C220 M5L/M5S PCIe SSD cable (1) for SFF & LFF chassis
RAID Controllers
Note: you may need some of the accessories if you are ordering the raid controller, please refer the RAID
controller accessories section below.
UCSC-RAID-M5=
Note: Supercap
(UCSC-SCAP-M5=), Cable
(CBL-SC-MR12GM5=),
(CBL-SC-MR12GM52=) included
when RAID card is ordered as a
spare
Cisco 12G Modular RAID controller with 2GB cache (supports max 16
drives)
UCSC-SAS-M5= Cisco 12G Modular SAS HBA for up to 16 drives
UCSC-9400-8E= Cisco 9400-8E 12G SAS HBA for external JBOD attach
Raid Controller accessories
UCSC-SCAP-M5= Super Cap for UCSC-RAID-M5, UCSC-MRAID1GB-KIT
CBL-SC-MR12GM5= Super Cap cable for UCSC-RAID-M5 for C220 M5 Servers
CBL-SC-MR12GM52= Super Cap cable for UCSC-RAID-M5 on C240 M5 Servers
Modular LAN on Motherboard (mLOM)
UCSC-MLOM-C100-04= Cisco UCS VIC 1497 Dual Port 40/100G QSFP28 CNA mLOM
UCSC-MLOM-C25Q-04= Cisco UCS VIC 1457 Quad Port 10/25G SFP28 mLOM
UCSC-MLOM-C40Q-03= Cisco UCS VIC 1387 Dual Port 40Gb QSFP+ CNA
UCSC-MLOM-IRJ45= Intel i350 Quad Port 1GBase-T NIC
Converged Network Adapters (CNAs)
UCSC-PCIE-C100-04= Cisco UCS VIC 1495 Dual Port 40/100G QSFP28 CNA PCIe
UCSC-PCIE-C40Q-03= Cisco UCS VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA
UCSC-PCIE-C25Q-04= Cisco UCS VIC 1455 Quad Port 10/25G SFP28 CNA PCIE
Network Interface Cards (NICs)
1 Gb NICs
UCSC-PCIE-IRJ45= Intel i350 Quad Port 1GBase-T NIC
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
82
10 Gb NICs
N2XX-AIPCI01= Intel X520 Dual Port 10Gb SFP+ NIC
UCSC-PCIE-ID10GC= Intel X550-T2 Dual Port 10GBase-T NIC
UCSC-PCIE-ID10GF= Intel X710-DA2 Dual Port 10Gb SFP+ NIC
UCSC-PCIE-IQ10GF= Intel X710 Quad Port 10Gb SFP+ NIC
UCSC-PCIE-IQ10GC= Intel X710 Quad Port 10GBase-T NIC
25 Gb NICs
UCSC-PCIE-QD25GF= Qlogic QL41212H Dual Port 25Gb NIC
UCSC-PCIE-ID25GF= Intel XXV710 Dual Port 25Gb SFP28 NIC
UCSC-P-M4D25GF= Mellanox MCX4121A-ACAT dual port 10/25G SFP28 NIC
40 Gb NICs
UCSC-PCIE-QD40GF= Qlogic QL45412H Dual Port 40Gb NIC
UCSC-PCIE-ID40GF= Intel XL710 Dual Port 40Gb QSFP+ NIC
100 Gb NICs
UCSC-PCIE-QS100GF= Qlogic QLE45611HLCU single port 100G NIC
PACK-QSFP-SFP= Packaging for QSFP 40G and SFP 10G
UCSC-LPBRKT-C40Q= Low Profile Bracket VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA
UCSC-LP-C25-1485= Low profile bracket for VIC
UCSC-LP-C40-1485= Low profile bracket for VIC1495
Host Bus Adapters (HBAs)
UCSC-PCIE-QD16GF= Qlogic QLE2692 Dual Port 16G Fibre Channel HBA
UCSC-PCIE-BD16GF= Emulex LPe31002 Dual Port 16G Fibre Channel HBA
UCSC-PCIE-QD32GF= Qlogic QLE2742 Dual Port 32G Fibre Channel HBA
UCSC-PCIE-BS32GF= Emulex LPe32000-M2 Single Port 32G Fibre Channel HBA
UCSC-PCIE-BD32GF= Emulex LPe32002-M2 Dual Port 32G Fibre Channel HBA
UCS NVMe/PCIe Add in Cards
CBL-NVME-C220FF= C220 M5L/M5S PCIe SSD cable (1) for SFF & LFF chassis
PCI Card accessories
UCSC-LPBRKT-C40Q= Low Profile Bracket VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
83
SPARE PARTS
UCSC-LP-C25-1485= Low profile bracket for VIC
UCSC-LP-C40-1485= Low profile bracket for VIC1495
SD Cards
UCS-SD-32G-S= 32 GB SD Card for UCS servers
UCS-SD-64G-S= 64 GB SD Card for UCS servers
UCS-SD-128G= 128GB SD Card for UCS servers
GPU PCIe Cards
UCSC-GPU-T4-16= NVIDIA T4 16GB
Power Supply
UCSC-PSU1-770W= 770W AC power supply for C-Series Servers Platinum
UCSC-PSU1-1050W= 1050W AC power supply for C-Series servers Platinum
UCSC-PSUV2-1050DC= 1050W DC power supply for C-Series servers Platinum
UCSC-PSU1-1600W= 1600W AC power supply for C-Series servers Platinum
UCSC-PSU1-1050ELV = 1050W AC Power Supply C-Series Enhanced Low Line Platinum
UCSC-PSU-M5BLK= Power Supply Blanking Panel for M5 servers
Power Cables
CAB-48DC-40A-8AWG= C-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A
CAB-N5K6A-NA= Power Cord, 200/240V 6A, North America
CAB-AC-L620-C13= AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft
CAB-C13-CBN= CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V
CAB-C13-C14-2M= CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V
CAB-C13-C14-AC= CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M
CAB-250V-10A-AR= Power Cord, 250V, 10A, Argentina
CAB-9K10A-AU= Power Cord, 250VAC 10A 3112 Plug, Australia
CAB-250V-10A-CN= AC Power Cord - 250V, 10A - PRC
CAB-9K10A-EU= Power Cord, 250VAC 10A CEE 7/7 Plug, EU
CAB-250V-10A-ID= Power Cord, SFS, 250V, 10A, India
CAB-250V-10A-IS= Power Cord, SFS, 250V, 10A, Israel
CAB-9K10A-IT= Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
84
CAB-9K10A-SW= Power Cord, 250VAC 10A MP232 Plug, Switzerland
CAB-9K10A-UK= Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK
CAB-9K12A-NA= Power Cord, 125VAC 13A NEMA 5-15 Plug, North America
CAB-250V-10A-BR= Power Cord - 250V, 10A - Brazil
CAB-C13-C14-2M-JP= Power Cord C13-C14, 2M/6.5ft Japan PSE mark
CAB-9K10A-KOR= Power Cord, 125VAC 13A KSC8305 Plug, Korea
CAB-ACTW= AC Power Cord (Taiwan), C13, EL 302, 2.3M
CAB-JPN-3PIN= Japan, 90-125VAC 12A NEMA 5-15 Plug, 2.4m
CAB-C13-C14-IN= Power Cord Jumper,C13-C14 Connectors,1.4 Meter Length, India
CAB-C13-C14-3M-IN= Power Cord Jumper, C13-C14 Connectors, 3 Meter Length, India
CMA
UCSC-CMA-M5= Reversible CMA for C220 M4 and M5 rack servers
USB Drive
UCS-USBFLSHB-16GB= UCS Servers 16 GB Flash USB Drive (optional)
TPM
UCSX-TPM2-001= Trusted Platform Module 1.2 for UCS Servers
UCSX-TPM2-002= Trusted Platform Module 2.0 for UCS servers
UCSC-INT-SW01= C220 M5 and C240 M5 Chassis Intrusion Switch
Bezel
UCSC-BZL-C220M5= C220 M5 Security Bezel
Software/Firmware
IMC Supervisor
CIMC-SUP-BASE-K9= IMC Supervisor One-time Site Installation License
CIMC-SUP-B01= IMC Supervisor-Branch Mgt SW for C-Series & E-Series up to 100 Svrs
CIMC-SUP-B02= IMC Supervisor- Branch Mgt SW for C & E-Series up to 250 Svrs
CIMC-SUP-B10= IMC Supervisor- Branch Mgt SW for C & E-Series up to 1K Svrs
CIMC-SUP-B25= IMC Supervisor Branch Mgt SW for C & E-Series 25 Svrs
CIMC-SUP-A01= IMC Supervisor Adv-Branch Mgt SW for C & E-Series 100 Svrs
CIMC-SUP-A02= IMC Supervisor Adv-Branch Mgt SW for C & E-Series 250 Svrs
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
85
SPARE PARTS
CIMC-SUP-A10= IMC Supervisor Adv-Branch Mgt SW for C & E-Series 1000 Svrs
CIMC-SUP-A25= IMC Supervisor Adv-Branch Mgt SW for C & E-Series 250 Svrs
EVAL-CIMC-SUP= EVAL: IMC Supervisor-Branch Mgt SW for C/E-Series - 50 Svrs
EVAL-CIMC-SUP-BAS= EVAL: IMC Supervisor One-time Site Installation License
UCS Multi-Domain Manager
UCS-MDMGR-1S= UCS Central Per Server License
NOTE: IF you must order quantity greater than 1 of UCS-MDMGR-1S,
you need to reference the UCS Central Per Server Data Sheet to order
the standalone PIDs: UCS-MDMGR-LIC= or UCS-MDMGR-1DMN=
VMware vCenter
VMW-VCS-STD-1A= VMware vCenter 7 Server Standard, 1 yr support required
VMW-VCS-STD-3A= VMware vCenter 7 Server Standard, 3 yr support required
VMW-VCS-STD-5A= VMware vCenter 7 Server Standard, 5 yr support required
VMW-VCS-FND-1A= VMware vCenter 7 Server Foundation (3 Host), 1 yr supp reqd
VMW-VCS-FND-3A= VMware vCenter 7 Server Foundation (3 Host), 3 yr supp reqd
VMW-VCS-FND-5A= VMware vCenter 7 Server Foundation (3 Host), 5 yr supp reqd
Red Hat
RHEL-2S2V-1A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req
RHEL-2S2V-3A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req
RHEL-2S2V-1S= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1-Yr SnS
RHEL-2S2V-3S= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3-Yr SnS
RHEL-2S-HA-1S= RHEL High Availability (1-2 CPU); Premium 1-yr SnS
RHEL-2S-HA-3S= RHEL High Availability (1-2 CPU); Premium 3-yr SnS
RHEL-2S-RS-1S= RHEL Resilient Storage (1-2 CPU); Premium 1-yr SnS
RHEL-2S-RS-3S= RHEL Resilient Storage (1-2 CPU); Premium 3-yr SnS
RHEL-2S2V-5A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req
RHEL-2S-HA-1A= RHEL High Availability (1-2 CPU); 1-Yr Support Reqd
RHEL-2S-HA-3A= RHEL High Availability (1-2 CPU); 3-Yr Support Reqd
RHEL-2S-HA-5A= RHEL High Availability (1-2 CPU); 5-Yr Support Reqd
RHEL-2S-RS-1A= RHEL Resilent Storage (1-2 CPU); Premium 1-yr SnS Reqd
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
86
RHEL-2S-RS-3A= RHEL Resilent Storage (1-2 CPU); Premium 3-yr SnS Reqd
RHEL-2S-RS-5A= RHEL Resilent Storage (1-2 CPU); Premium 5-yr SnS Reqd
Red Hat SAP
RHEL-SAP-2S2V-1S= RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS Reqd
RHEL-SAP-2S2V-3S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS Reqd
RHEL-SAPSP-3S RHEL SAP Solutions Premium - License with 3 Years of SnS
RHEL-SAPSS-3S RHEL SAP Solutions Standard - License with 3 Years of SnS
VMware
VMW-VSP-STD-1A= VMware vSphere 7 Std (1 CPU, 32 Core) 1-yr, Support Required
VMW-VSP-STD-3A= VMware vSphere 7 Std (1 CPU, 32 Core) 3-yr, Support Required
VMW-VSP-STD-5A= VMware vSphere 7 Std (1 CPU, 32 Core) 5-yr, Support Required
VMW-VSP-EPL-1A= VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 1Yr, Support Reqd
VMW-VSP-EPL-3A= VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 3Yr, Support Reqd
VMW-VSP-EPL-5A= VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 5Yr, Support Reqd
SLES and SAP
SLES-SAP-2S2V-1A= SLES for SAP Apps (1-2 CPU, 1-2 VM); 1-Yr Support Reqd
SLES-SAP-2SUV-1A= SLES for SAP Apps (1-2 CPU, Unl VM); 1-Yr Support Reqd
SLES-SAP-2S2V-3A= SLES for SAP Apps (1-2 CPU, 1-2 VM); 3-Yr Support Reqd
SLES-SAP-2SUV-3A= SLES for SAP Apps (1-2 CPU, Unl VM); 3-Yr Support Reqd
SLES-SAP-2S2V-5A= SLES for SAP Apps (1-2 CPU, 1-2 VM); 5-Yr Support Reqd
SLES-SAP-2SUV-5A= SLES for SAP Apps (1-2 CPU, Unl VM); 5-Yr Support Reqd
SLES-SAP-2S2V-1S= SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS
SLES-SAP-2SUV-1S= SLES for SAP Apps (1-2 CPU, Unl VM); Priority 1-Yr SnS
SLES-SAP-2S2V-3S= SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS
SLES-SAP-2SUV-3S= SLES for SAP Apps (1-2 CPU, Unl VM); Priority 3-Yr SnS
SLES-SAP-2S2V-5S= SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS
SLES-SAP-2SUV-5S= SLES for SAP Apps (1-2 CPU, Unl VM); Priority 5-Yr SnS
SUSE
SLES-2S2V-1A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
87
SPARE PARTS
SLES-2SUV-1A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 1-Yr Support Req
SLES-2S2V-3A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req
SLES-2SUV-3A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 3-Yr Support Req
SLES-2S2V-5A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req
SLES-2SUV-5A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 5-Yr Support Req
SLES-2S2V-1S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS
SLES-2SUV-1S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 1-Yr SnS
SLES-2S2V-3S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS
SLES-2SUV-3S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 3-Yr SnS
SLES-2S2V-5S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS
SLES-2SUV-5S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 5-Yr SnS
SLES-2S-HA-1S= SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS
SLES-2S-HA-3S= SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS
SLES-2S-HA-5S= SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS
SLES-2S-GC-1S= SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns
SLES-2S-GC-3S= SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS
SLES-2S-GC-5S= SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS
SLES-2S-LP-1S= SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required
SLES-2S-LP-3S= SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required
Microsoft
MSWS-19-DC16C= Windows Server 2019 Data Center (16 Cores/Unlimited VMs)
MSWS-19-DC16C-NS= Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC
MSWS-19-ST16C= Windows Server 2019 Standard (16 Cores/2 VMs)
MSWS-19-ST16C-NS= Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC
MSWS-22-ST16C= Windows Server 2022 Standard (16 Cores/2 VMs)
MSWS-22-ST16C-NS= Windows Server 2022 Standard (16 Cores/2 VMs) - No Cisco SVC
MSWS-22-DC16C= Windows Server 2022 Data Center (16 Cores/Unlimited VMs)
MSWS-22-DC16C-NS= Windows Server 2022 DC (16 Cores/Unlim VMs) - No Cisco SVC
Table 38 Spare Parts (continued)
Product ID (PID) PID Description
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
88
Please refer to “Cisco UCS C220 M5 Server Installation and Service Guide” for installation procedures. See
this link:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M5/install/C220M5.html
Notes:
1. This part is included with the purchase of option or spare CPU or CPU processor kits.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
89
SPARE PARTS
Memory Support for CPU Classes and CPU Modes
For 2
nd
Generation Intel
®
Xeon
®
Scalable Processors:
DIMMs and PMem are supported
CPU PIDs ending in “M” support up to a limit of 2048 GB per CPU
CPU PIDs ending in “L” support up to a limit of 4608 GB per CPU
All other CPU PIDs support up to a limit of 1024 GB per CPU
For the App Direct Mode, both PMem and DIMM capacities count towards the CPU capacity limit
For the Memory Mode and Mixed Mode only the PMem capacity counts towards the CPU capacity
limit
For Configurations Using Only DIMMs
CPU PIDs ending in “M” support DIMM capacities up to 1536 GB per CPU (using 12 x 128 GB
DIMMs) and DIMM capacities up to 2048 GB per CPU (using 8 x 256 GB DIMMs).
CPU PIDs ending in “L” support DIMM capacities up to 1536 GB per CPU (using 12 x 128 GB
DIMMs) and DIMM capacities up to 3072 GB per CPU (using 12 x 256 GB DIMMs). The 4608 GB
limit cannot be reached with these capacity DIMMs.
CPU PIDs not ending in “L” or “M” support DIMM capacities up to 1024 GB per CPU (using 8 x
128 GB DIMMs or 4 x 256 GB DIMMs).
For Configurations Using DIMMs and PMem in
App Direct Mode
CPU PIDs ending in “M” support capacities up to 1792 GB per CPU (using 6 x 128 GB DIMMS
and 2 x 512 GB PMem or 4 x 256 GB PMem) or up to 2048 GB per CPU (using 6 x 256 GB DIMMs
and 2 x 256 GB PMem or 6 x 256 GB DIMMs and 4 x 128 GB PMem)
CPU PIDs ending in “L” support capacities up to 3840 GB per CPU (using 6 x 128 GB DIMMs
and 6 x 512 GB PMem) or up to 4608 GB per CPU (using 6 x 256 GB DIMMs and 6 x 512 GB
PMem)
CPU PIDs not ending in “L” or “M” support capacities up to 1024 GB per CPU (using 6 x 128
GB DIMMs and 2 x 128 GB PMem).
For Configurations Using DIMMs and PMem in
Memory or Mixed Mode
NOTE: For Memory and Mixed Modes, DIMMs are used as cache and do not factor into
CPU capacity.
CPU PIDs ending in “M” support capacities up to 2048 GB per CPU using:
6 x 128 GB DIMMs as cache and 4 x 512 GB PMem as memory, or
6x 256 GB DIMMs as cache and 4 x 512 GB PMem as memory
CPU PIDs ending in “L” support capacities up to 3072 GB using:
6 x 128 GB DIMMs as cache and 6 x 512 GB PMem as memory, or
6 x 256 GB DIMMs as cache and 6 x 512 GB PMem as memory
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
90
The allowable 4608 limit for PMem capacity is not reached in this case.
CPU PIDs not ending in “L” or “M” support capacities up to 1024 GB per CPU using:
6 x 128 GB DIMMs as cache and 2 x 512 GB PMem as memory, or
6 x 256 GB DIMMs as cache and 2 x 512 GB PMem as memory
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
91
UPGRADING or REPLACING CPUs
UPGRADING or REPLACING CPUs
NOTE: Before servicing any CPU, do the following:
Decommission and power off the server.
Slide the C220 M5 server out from the rack.
Remove the top cover.
To replace an existing CPU, follow these steps:
(1) Have the following tools and materials availabl
e for the procedure:
T-30 Torx driver—Supplied with replacement CPU.
#1 flat-head screwdriver—Supplied with replacement CPU.
CPU assembly tool—Supplied with replacement CPU. Can be ordered separately as Cisco PID
UCS-CPUAT=.
Heatsink cleaning kit—Supplied with replacement CPU. Can be ordered separately as Cisco
PID UCSX-HSCK=.
Thermal interface material (TIM)—Syringe supplied with replacement CPU. Can be ordered
separately as Cisco PID UCS-CPU-TIM=.
(2) Order the appropriate replacement CPU from T
able 3 on page 13
(3) Carefully remove and replace the CPU and heatsink in accordance with the instructions
found in “Cisco UCS C220 M5 Server Installation and Service Guide,” found at:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M5/install/C220M5/C
220M5_chapter_010.html#concept_bfk_kwp_hz.
To add a new CPU, follow these steps:
(1) Have the following tools and materials availabl
e for the procedure:
T-30 Torx driver—Supplied with new CPU.
#1 flat-head screwdriver—Supplied with new CPU
CPU assembly tool—Supplied with new CPU.Can be ordered separately as Cisco PID
UCS-CPUAT=
Thermal interface material (TIM)—Syringe supplied with replacement CPU.Can be ordered
separately as Cisco PID UCS-CPU-TIM=
(2) Order the appropriate new CPU from Table 3 on page 13
(3) Order one heat sink for each new CPU. Order PID UCSC-HS-C220M5= for CPUs that dissipate
150 W or less. Order PID UCSC-HS2-C220M5= for CPUs that dissipate more than 150 W.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
UPGRADING or REPLACING MEMORY
92
(4) Carefully install the CPU and heatsink in accordance with the instructions found in “Cisco
UCS C220 M5 Server Installation and Service Guide,” found at:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M5/install/C220M5/C
220M5_chapter_010.html#concept_bfk_kwp_hz.
UPGRADING or REPLACING MEMORY
NOTE: Before servicing any DIMM or PMem, do the following:
Decommission and power off the server.
Remove the top cover from the server
Slide the server out the front of the chassis.
To add or replace DIMMs or PMem, follow these steps:
(1) Order new DIMMs or PMem as needed from Table 4 on page 19.
(2) Open both connector latches and remove and replace the DIMM/PMem as needed.
Figure 13
Replacing Memory
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
93
UPGRADING or REPLACING MEMORY
(3) Press evenly on both ends of the DIMM/PMem until it clicks into place in its slot.
(4) Press the connector latches inward slightly to seat them fully.
For additional details on replacing or upgrading DIMMs and PMem, see “Cisco UCS C220 M5
Server Installation and Service Guide,” found at these links:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M5/install/C220M
5/C220M5_chapter_010.html#concept_c53_tbp_hz
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M5/install/C220M
5/C220M5_chapter_010.html#concept_b1k_mbt_tgb
NOTE: Ensure that the notch in the DIMM/PMem aligns with the slot. If the notch is
misaligned, it is possible to damage the DIMM/PMem, the slot, or both.
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
94
DISCONTINUED EOL PRODUCTS
Below is the list of parts were previously available for this product and are no longer sold. Please refer to
the EOL Bulletin Links via the
Ta b l e 39 below to determine if still supported.
Table 39 EOL Products
EOS option PID Description EOL bulletin link
DRIVES
HDDs
UCS-HD300G10NK9 300GB 12G SAS 10K RPM SFF HDD (SED)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-740779.html
Self-Encrypted Drives (SED)
UCS-SD800GBENK9 800 GB Enterprise performance SAS SSD
(10X DWPD, SED) (Micron S650DC)
FIPS140-2
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-740779.html
UCS-SD480GBHTNK9 480GB Enterprise Value SAS SSD (1X
DWPD, SED)
FIPS140-2
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742823.html
UCS-SD38TBHTNK9 3.8TB Enterprise value SAS SSD (1X
DWPD, SED)
FIPS140-2
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742823.html
UCS-SD16TBHNK9 1.6 TB Enterprise performance SAS SSD
(10X DWPD, SED) FIPS140-2
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-SD960GBHTNK9 960GB Enterprise value SAS SSD (1X
DWPD, SED)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
NVMe
UCSC-NVMELW-I500
500GB 2.5in U.2 Intel P4501 NVMe Med.
Perf. Value Endurance
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742509.html
UCSC-NVMEXP-I375 375GB 2.5in Intel Optane NVMe Extreme
Perf.
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742509.html
UCSC-NVMELW-I1000 Cisco 2.5" U.2 1TB Intel P4501 NVMe
Med. Perf. Value Endur (Intel)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742509.html
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
95
DISCONTINUED EOL PRODUCTS
UCSC-NVMEHW-I1000 Cisco 2.5" U.2 1.0 TB Intel P4500 NVMe
High Perf. Value Endur (Intel)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742509.html
UCSC-NVMEHW-I1600 Cisco 2.5" U.2 1.6TB Intel P4600 NVMe
High Perf. High Endurance
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742823.html
UCSC-NVMELW-I2000 Cisco 2.5" U.2 2TB Intel P4501 NVMe
Perf. Value Endur (Intel)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742509.html
UCSC-NVMEHW-I2000 Cisco 2.5" U.2 2.0 TB Intel P4600 NVMe
High Perf. High Endur (Intel)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742823.html
UCSC-NVMEHW-I4000 Cisco 2.5" U.2 4.0 TB Intel P4500 NVMe
High Perf. Value Endur (Intel)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742509.html
UCSC-NVMEHW-I2TBV 2TB 2.5in U.2 Intel P4500 NVMe High
Perf. Value Endurance
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742823.html
UCSC-NVMEHW-I3200 3.2TB 2.5in U.2 Intel P4600 NVMe High
Perf. High Endurance
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742823.html
UCSC-NVMEHW-H1600 Cisco 2.5" U.2 1.6TB HGST SN200 NVMe
High Perf. High Endurance
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCSC-NVMEHW-H3200 3.2TB 2.5in U.2 HGST SN200 NVMe High
Perf. High Endurance
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCSC-NVME-H32003 Cisco HHHL AIC 3.2T HGST SN260 NVMe
Extreme Perf High Endrnc
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-2412151.html
UCSC-NVMEHW-H6400 6.4TB HGST SN200 NVMe High Perf. High
Endurance (HGST)
https://www.cisco.com/c/en/us/products/collateral
/hyperconverged-infrastructure/hyperflex-hx-series
/eos-eol-notice-c51-2451489.html
UCSC-NVME-H38401 Cisco HHHL AIC 3.8TB HGST SN260 NVMe
Extreme Performance High Endurance
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-2412151.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
96
UCSC-NVME-H64003 Cisco HHHL AIC 6.4T HGST SN260 NVMe
Extreme Perf High Endrnc
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-2412151.html
UCSC-NVMEHW-H7680 7.7TB 2.5in U.2 HGST SN200 NVMe High
Perf. Value Endurance
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCSC-NVMEHW-H800 800GB 2.5in U.2 HGST SN200 NVMe High
Perf. High Endurance
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCSC-NVME2H-I2TBV Cisco 2.5" U.2 2.0TB Intel P4510 NVMe
High Perf. Value Endurance
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hyperflex-accessories-eol3.html
UCSC-NVME2H-I1000 Cisco 2.5" U.2 1,0 TB Intel P4510 NVMe
High Perf. Value Endu
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/select-ucs-hyperflex-accessories-eol3.html
UCSC-NVME2H-I4000 Cisco 2.5" U.2 4.0TB Intel P4510 NVMe
High Perf. Value Endu
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/select-ucs-hyperflex-accessories-eol3.html
UCS-M2-240GB 240GB M.2 SATA Micron G1 SSD
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
UCS-M2-960GB 960GB M.2 SATA Micron G1 SSD
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
UCS-NVMEM6-W6400 6.4TB 2.5in U.2 WD SN840NVMe
Extreme Perf. High Endurance
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
UCS-NVMEM6-W6400 6.4TB 2.5in U.2 WD SN840NVMe
Extreme Perf. High Endurance
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
UCS-SD76T61X-EV 7.6TB 2.5 inch Enterprise Value 6G SATA
SSD
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
UCS-SD76TBEM2NK9 7.6TB 2.5in Enter Value 6G SATA Micron
G1 SSD (SED)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
UCS-SD960GBM2NK9 960GB 2.5in Enter Value 6G SATA Micron
G1 SSD (SED)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
97
DISCONTINUED EOL PRODUCTS
UCSC-NVME2H-I3200 Cisco 2.5" U.2 3.2TB Intel P4610 NVMe
High Perf. High Endu
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
UCSC-NVMEHW-I8000 8TB 2.5in U.2 Intel P4510 NVMe High
Perf. Value Endurance
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/unified-computing-accessories-eol.html
UCS-SD960G2HTNK9 960GB Enterprise Value SSD 12G SAS SED
FIPS
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCSC-F-H16003 Cisco HHHL AIC 1.6T HGST SN260 NVMe
Extreme Perf High Endrnc
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCSC-NVME-H76801 Cisco HHHL 7.7T HGST SN260 NVMe
Extreme Perf Value Enderance
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCSC-NVME2H-I1600 Cisco 2.5" U.2 1.6TB Intel P4610 NVMe
High Perf. High Endu
http://https://www.cisco.com/c/en/us/products/
collateral/servers-unified-computing/ucs-c-series-
rack-servers/select-ucs-hyperflex-accessories-eol3
.html-eol.cisco.com/eol/pbReport.html?id=ID1031
408
Enterprise Performance SSDs
UCS-SD600GBE3NK9 600GB Enterprise performance SATA SSD
(3X DWPD, SED)
Non FIPS
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-742823.html
UCS-SD400G12TX-EP 400 GB 2.5 inch Enterprise performance
12G SAS SSD (10X DWPD)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-b-series-blade-serv
ers/eos-eol-notice-c51-742066.html
UCS-SD800H123X-EP 800GB 2.5in Enterprise performance 12G
SAS SSD(3X endurance)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-SD400H123X-EP 400GB 2.5in Enterprise performance 12G
SAS SSD(3X endurance)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-b-series-blade-s
ervers/eos-eol-notice-c51-742066.html
UCS-SD16TBENK9 1.6TB Enterprise performance SAS SSD
(10XDWPD, SED)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD800G12TX-EP 800 GB 2.5 inch Enterprise performance
12G SAS SSD (10X DWPD)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD16TB12TX-EP 1.6TB 2.5 inch Enterprise performance
12G SAS SSD(10X DWPD)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741644.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
98
UCS-SD32H123X-EP 3.2TB 2.5in Enterprise performance 12G
SAS SSD(3X endurance)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-SD400GBHNK9 400GB Enterprise performance SAS SSD
(10X DWPD, SED) FIPS140-2
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-743832.html
UCS-SD400GBENK9 400GB Enterprise performance SAS SSD
(10X DWPD, SED)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-740779.html
UCS-SD400G123X-EP 400 GB 2.5 inch Enterprise performance
12G SAS SSD(3X DWPD)
https://www.cisco.com/c/en/us/products/collateral
/hyperconverged-infrastructure/hyperflex-hx-series
/eos-eol-notice-c51-2451489.html
UCS-SD32T123X-EP 3.2 TB 2.5 inch Enterprise performance
12G SAS SSD(3X DWPD)
https://www.cisco.com/c/en/us/products/collateral
/hyperconverged-infrastructure/hyperflex-hx-series
/eos-eol-notice-c51-2451489.html
UCS-SD16T123X-EP 1.6 TB 2.5 inch Enterprise performance
12G SAS SSD(3X DWPD)
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCS-SD800GBHNK9 800GB Enterprise performance SAS SSD
(10X DWPD, SED)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/ucs-hyperflex-accessories-eol.html
UCS-SD800G123X-EP 800 GB 2.5 inch Enterprise performance
12G SAS SSD(3X DWPD)
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCS-SD16H123X-EP 1.6 TB 2.5inch Enterprise performance
12G SAS SSD(3X endurance)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-743832.html
Enterprise Value
UCS-SD480GH61X-EV 480 GB 2.5 inch Enterprise Value 12G
SAS SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rver s/eos-eol-notice-c51-743832.html
UCS-SD19TH61X-EV 1.9 TB 2.5 inch Enterprise Value 12G SAS
SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-743832.html
UCS-SD480G2HNK9 480GB Enterprise value SAS SSD (1X
DWPD, SED)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rver s/eos-eol-notice-c51-743832.html
UCS-SD38TBE1NK9 3.8TB Enterprise Value SSD (SATA) (1X
DWPD, SED)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744204.html
UCS-SD16T61X-EV 1.6TB 2.5 inch Enterprise Value 6G SATA
SSD
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-741895.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
99
DISCONTINUED EOL PRODUCTS
UCS-SD480G61X-EV 480 GB 2.5 inch Enterprise Value 6G
SATA SSD
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-741644.html
UCS-SD240G61X-EV
240GB 2.5 inch Enterprise Value 6G
SATA SSD
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-b-series-blade-serv
ers/eos-eol-notice-c51-742066.html
UCS-SD240GBE1NK9 240GB Enterprise Value SSD (SATA) (1X
DWPD, SED)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742509.html
UCS-SD150G61X-EV 150 GB 2.5 inch Enterprise Value 6G
SATA SSD (Intel S3520)
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-742509.html
UCS-SD38TH61X-EV 3.8 TB 2.5 inch Enterprise Value 12G SAS
SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-743832.html
UCS-SD19TB121X-EV 1.9 TB 2.5 inch Enterprise Value 12G SAS
SSD (Toshiba PM4)
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCS-SD38TB121X-EV 3.8 TB 2.5 inch Enterprise Value 12G SAS
SSD (Toshiba PM4)
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCS-SD960G121X-EV 960 GB 2.5 inch Enterprise Value 12G
SAS SSD (Toshiba PM4)
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCS-SD960GH61X-EV 960 GB 2.5 inch Enterprise Value 12G
SAS SSD
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCS-SD480G121X-EV 480GB 2.5 inch Enterprise Value 12G
SAS SSD
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCS-SD38T2HTNK9 3.8TB Enterprise Value SSD 12G SAS SED
FIPS
https://www.cisco.com/c/en/us/products/collate
ral/hyperconverged-infrastructure/hyperflex-hx-se
ries/eos-eol-notice-c51-2451489.html
UCS-SD960GBE1NK9 960GB Enterprise value SATA SSD (1X
DWPD, SED)
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744204.html
UCS-SD960GS1X-EV 960GB Enterprise value https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744204.html
UCS-SD16TM1X-EV 1.6TB 2.5in Enter Value 6G SATA Micron
G1 SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
100
UCS-SD38TM1X-EV 3.8TB 2.5in Enter Value 6G SATA Micron
G1 SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD960G61X-EV 960GB 2.5 inch Enterprise Value 6G SATA
SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hyperflex-accessories-eol2.html
UCS-SD240GM1X-EV 240GB 2.5in Enter Value 6G SATA Micron
G1 SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD480GM1X-EV 480 GB 2.5in Enter Value 6G SATA Micron
G1 SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD76TM1X-EV 7.6TB 2.5in Enter Value 6G SATA Micron
G1 SSD
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
CPU
UCS-CPU-I8280M Intel 8280M 2.7GHz/205W 28C/38.50MB
3DX DDR4 2TB 2933 MHz
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-CPU-I8276M Intel 8276M 2.2GHz/165W 28C/38.50MB
3DX DDR4 2TB 2933 MHz
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-CPU-I8260M Intel 8260M 2.4GHz/165W 24C/35.75MB
3DX DDR4 2TB 2933 MHz
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-CPU-I6240M Intel 6240M 2.6GHz/150W 18C/24.75MB
3DX DDR4 2TB 2933 MHz
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-CPU-I6238M Intel 6238M 2.1GHz/140W 22C/30.25MB
3DX DDR4 2TB 2933 MHz
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-CPU-I5215M Intel 5215M 2.5GHz/85W 10C/13.75MB
3DX DDR4 2TB 2666MHz
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-743832.html
UCS-CPU-8180M 2.5 GHz 8180M/205W 28C/38.50MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8176M 2.1 GHz 8176M/165W 28C/38.50MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8170M 2.1 GHz 8170M/165W 26C/35.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
101
DISCONTINUED EOL PRODUCTS
UCS-CPU-8160M 2.1 GHz 8160M/150W 24C/33MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8180 2.5 GHz 8180/205W 28C/38.50MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8176 2.1 GHz 8176/165W 28C/38.50MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8170 2.1 GHz 8170/165W 26C/35.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8168 2.7 GHz 8168/205W 24C/33MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8164 2.0 GHz 8164/150W 26C/35.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8160T 2.1 GHz 8160/150W 24C/33MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8160 2.1 GHz 8160/150W 24C/33MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8158 3.0 GHz 8158/150W 12C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8156 3.6 GHz 8156/105W 4C/16.50MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-8153 2.0 GHz 8153/125W 16C/22MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6142M 2.6 GHz 6142M/150W 16C/22MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6140M 2.3 GHz 6140M/140W 18C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6134M 3.2 GHz 6134M/130W 8C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6154 3.0 GHz 6154/200W 18C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6152 2.1 GHz 6152/140W 22C/30.25MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
102
UCS-CPU-6150 2.7 GHz 6150/165W 18C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6148 2.4 GHz 6148/150W 20C/27.50MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6144 3.5 GHz 6144/150W 8C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6142 2.6 GHz 6142/150W 16C/22MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6140 2.3 GHz 6140/140W 18C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6138T 2.0 GHz 6138T/125W 20C/27.5MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6138 2.0 GHz 6138/125W 20C/27.50MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6136 3.0 GHz 6136/150W 12C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6134 3.2 GHz 6134/130W 8C/24.75MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6132 2.6 GHz 6132/140W 14C/19.25MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6130 2.1 GHz 6130/125W 16C/22MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6128 3.4 GHz 6128/115W 6C/19.25MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-6126 2.6 GHz 6126/125W 12C/19.25MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-5122 3.6 GHz 5122/105W 4C/16.50MB
Cache/DDR4 2666MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-5120 2.2 GHz 5120/105W 14C/19.25MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-5118 2.3 GHz 5118/105W 12C/16.50MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
103
DISCONTINUED EOL PRODUCTS
UCS-CPU-5117 2.0 GHz 5117/105W 14C/19.25MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-5115 2.4 GHz 5115/85W 10C/13.75MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-I3204 Intel 3204 1.9GHz/85W 6C/8.25MB DDR4
2133MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-accessories-eol.html
UCS-CPU-I4214Y Intel 4214Y SS 2.2GHz/85W 12/10/8C
16.75MB DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-accessories-eol.html
UCS-CPU-I6250 Intel 6250 3.9GHz/185W 8C/35.75MB
PMM DDR4 1TB 2933 MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-accessories-eol.html
UCS-CPU-I6252N Intel 6252N 2.3GHz/150W 24C/35.75MB
DCP DDR4 2933 MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-accessories-eol.html
UCS-CPU-4116 2.1 GHz 4116/85W 12C/16.50MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-4114 2.2 GHz 4114/85W 10C/13.75MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-4112 2.6 GHz 4112/85W 4C/8.25MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-4110 2.1 GHz 4110/85W 8C/11MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-4108 1.8 GHz 4108/85W 8C/11MB
Cache/DDR4 2400MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-3106 1.7 GHz 3106/85W 8C/11MB
Cache/DDR4 2133MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
UCS-CPU-3104 1.7 GHz 3104/85W 6C/8.25MB
Cache/DDR4 2133MHz
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-744580.html
MEMORY
UCS-MR-X8G1RS-H 8GB DDR4-2666-MHz
RDIMM/PC4-21300/single rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-740780.html
UCS-MR-X16G2RS-H 16GB DDR4-2666-MHz
RDIMM/PC4-21300/dual rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-740780.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
104
UCS-MR-X16G1RT-H 16GB DDR4-2933MHz RDIMM 1Rx4
(8Gb)/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/ucs-hyperflex-accessories-eol14611.html
UCS-MR-X32G2RT-H 32GB DDR4-2933MHz RDIMM 2Rx4
(8Gb)/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/ucs-hyperflex-accessories-eol14611.html
UCS-MR-X64G2RT-H 64GB DDR4-2933MHz RDIMM 2Rx4
(16Gb)/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/ucs-hyperflex-accessories-eol14611.html
UCS-ML-X64G4RT-H 64GB DDR4-2933MHz LRDIMM 4Rx4
(8Gb)/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/ucs-hyperflex-accessories-eol14611.html
UCS-ML-128G4RT-H 128GB DDR4-2933MHz LRDIMM 4Rx4
(16Gb)/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/ucs-hyperflex-accessories-eol14611.html
UCS-ML-X64G4RS-H 64GB DDR4-2666-MHz
LRDIMM/PC4-21300/quad rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-2412151.html
UCS-ML-X64G4RS-H 64GB DDR4-2666-MHz
LRDIMM/PC4-21300/quad rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collateral
/servers-unified-computing/ucs-c-series-rack-server
s/eos-eol-notice-c51-2412151.html
UCS-ML-X32G2RS-H 32GB DDR4-2666-MHz
LRDIMM/PC4-21300/dual rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-ML-X32G2RSHM 32GB DDR4-2666-MHz LRDIMM/dual
rank/x4/1.2v. Micron only
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-ML-X64G4RS-H 64GB DDR4-2666-MHz
LRDIMM/PC4-21300/quad rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-ML-X64G4RSHM 64GB DDR4-2666-MHz LRDIMM/quad
rank/x4/1.2v. Micron only
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-ML-X64G4RSHS 64GB DDR4-2666-MHz LRDIMM/quad
rank/x4/1.2v. Samsung only
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-MR-128G8RS-H 128GB DDR4-2666-MHz
TSV-RDIMM/PC4-21300/octal
rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
105
DISCONTINUED EOL PRODUCTS
UCS-MR-X16G1RS-H 16GB DDR4-2666-MHz
RDIMM/PC4-21300/single rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-MR-X16G1RSHM 16GB DDR4-2666-MHz RDIMM/single
rank/x4/1.2v. Micron only
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-MR-X32G2RS-H 32GB DDR4-2666-MHz
RDIMM/PC4-21300/dual rank/x4/1.2v
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-MR-X32G2RSHM 32GB DDR4-2666-MHz RDIMM/dual
rank/x4/1.2v. Micron only
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-MR-X32G2RSHS 32GB DDR4-2666-MHz RDIMM/dual
rank/x4/1.2v. Samsung only
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-MR-X64G4RS-H 64GB DDR4-2666-MHz
TSV-RDIMM/PC4-21300/quad
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-2412151.html
UCS-ML-256G8RT-H 256GB DDR4-2933-MHz
LRDIMM/8Rx4/1.2v
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-b-series-blade-s
ervers/select-ucs-accessories-eol.html
PCIe OPTION CARD
UCSC-PCIE-Q2672 Qlogic QLE2672-CSC, 16Gb Fibre
Channel HBA with SR Optics
https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
Microsoft Windows server
MSWS-16-ST16C Windows Server 2016 Standard (16
Cores/2 VMs)
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-ST24C Windows Server 2016 Standard (24
Cores/2 VMs)
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-ST16C-NS Windows Server 2016 Standard (16
Cores/2 VMs) - No Cisco SVC
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-ST24C-NS Windows Server 2016 Standard (24
Cores/2 VMs) - No Cisco SVC
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-DC16C Windows Server 2016 Data Center (16
Cores/Unlimited VMs)
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-DC24C Windows Server 2016 Data Center (24
Cores/Unlimited VMs)
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-DC16C-NS Windows Server 2016 DC (16
Cores/Unlim VMs) - No Cisco SVC
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
106
MSWS-16-DC24C-NS Windows Server 2016 DC (24
Cores/Unlim VMs) - No Cisco SVC
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
OS Media
MSWS-16-ST16C-RM Windows Server 2016 Std (16 Cores/2
VMs) - Recovery Media
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-ST24C-RM Windows Server 2016 Std (24 Cores/2
VMs) - Recovery Media
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-DC16C-RM Windows Server 2016 DC (16
Cores/Unlim VMs) - Recovery Media
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
MSWS-16-DC24C-RM Windows Server 2016 DC (24
Cores/Unlim VMs) - Recovery Media
https://www.cisco.com/c/en/us/products/servers
-unified-computing/ucs-c-series-rack-servers/eos-
eol-notice-c51-743145.html
SPARES
UCSC-MLOM-BLK= MLOM Blanking Panel
https://www.cisco.com/c/en/us/products/collatera
l/servers-unified-computing/ucs-c-series-rack-serve
rs/eos-eol-notice-c51-742012.html
GPU
UCSC-GPU-P100-12G NVIDIA P100 12GB
https://www.cisco.com/c/en/us/products/collater
al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-741579.html
UCSC-GPU-P100-16G NVIDIA P100 16GB
https://www.cisco.com/c/en/us/products/collater
al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-741579.html
Operating system
SLES-2SUV-1A SUSE Linux Enterprise Svr (1-2 CPU,Unl
VM); 1-Yr Support Req
SLES-2SUV-1S SUSE Linux Enterprise Svr (1-2 CPU,Unl
VM); Prio 1-Yr SnS
SLES-2SUV-3A SUSE Linux Enterprise Svr (1-2 CPU,Unl
VM); 3-Yr Support Req
SLES-2SUV-3S SUSE Linux Enterprise Svr (1-2 CPU,Unl
VM); Prio 3-Yr SnS
SLES-2SUV-5A SUSE Linux Enterprise Svr (1-2 CPU,Unl
VM); 5-Yr Support Req
SLES-2SUV-5S SUSE Linux Enterprise Svr (1-2 CPU,Unl
VM); Prio 5-Yr SnS
SLES-SAP-2SUV-1A SLES for SAP Apps w/ HA (1-2 CPU, Unl
VM); 1-Yr Support Reqd
SLES-SAP-2SUV-1S SLES for SAP Apps (1-2 CPU, Unl VM);
Priority 1-Yr SnS
SLES-SAP-2SUV-3A SLES for SAP Apps w/ HA (1-2 CPU, Unl
VM); 3-Yr Support Reqd
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
107
DISCONTINUED EOL PRODUCTS
SLES-SAP-2SUV-3S SLES for SAP Apps (1-2 CPU, Unl VM);
Priority 3-Yr SnS
SLES-SAP-2SUV-5A SLES for SAP Apps w/ HA (1-2 CPU, Unl
VM); 5-Yr Support Reqd
SLES-SAP-2SUV-5S SLES for SAP Apps (1-2 CPU, Unl VM);
Priority 5-Yr SnS
Table 39 EOL Products
EOS option PID Description EOL bulletin link
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
108
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Table 40 UCS C220 M5 Dimensions and Weight
Parameter Value
Height 1.7 in. (4.32 cm)
Width 16.89 in. (43.0 cm)
including handles:
18.98 in. (48.2 cm)
Depth 29.8 in. (75.6 cm)
including handles:
30.98 in. (78.7 cm)
Front Clearance 3 in. (76 mm)
Side Clearance 1 in. (25 mm)
Rear Clearance 6 in. (152 mm)
Weight
Maximum (10 HDDs, 2 CPUs, 24 D
IMMs, two power supplies) 60.0 lbs (27.2 kg)
Minimum (1 HDD, 1 CPU, 1 DIMM, one power supply) 29.0 lbs (13.2 kg)
Bare (0 HDD, 0 CPU, 0 DIMM, one power supply) 26.7 lbs (12.1 kg)
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
109
TECHNICAL SPECIFICATIONS
Power Specifications
The server is available with the following types of power supplies:
770 W (AC) power supply (see Ta b l e 41).
1050 W (AC) power supply (see Ta b le 42).
1050 W V2 (DC) power supply (see Ta b l e 43)
1600 W (AC) power supply (see Ta b le 44)
Table 41 UCS C220 M5 SFF Power Specifications (770 W AC power supply)
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W) 770
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 8.8 7.4 4.2 3.8
Maximum Input at Nominal Input Voltage (W) 855 855 855 846
Maximum Input at Nominal Input Voltage (VA) 882 882 882 872
Minimum Rated Efficiency (%)
1
90 90 90 91
Minimum Rated Power Factor
1
0.97 0.97 0.97 0.97
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)
2
12
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Table 42 UCS C220 M5 1050 W (AC) Power Supply Specifications
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)
1
800 1050
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
110
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 9.2 7.6 5.8 5.2
Maximum Input at Nominal Input Voltage (W) 889 889 1167 1154
Maximum Input at Nominal Input Voltage (VA) 916 916 1203 1190
Minimum Rated Efficiency (%)
2
90 90 90 91
Minimum Rated Power Factor
2
0.97 0.97 0.97 0.97
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)
3
12
Table 43 UCS C220 M5 1050 W (DC) Power Supply Specifications
Parameter Specification
Input Connector Molex 42820
Input Voltage Range (Vrms) -48
Maximum Allowable Input Voltage Range (V rms) -40 to -72
Frequency Range (Hz) NA
Maximum Allowable Frequency Range (Hz) NA
Maximum Rated Output (W) 1050
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) -48
Nominal Input Current (Arms) 24
Maximum Input at Nominal Input Voltage (W) 1154
Maximum Input at Nominal Input Voltage (VA) 1154
Minimum Rated Efficiency (%)
1
91
Minimum Rated Power Factor
1
NA
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)
2
5
Notes:
1. Maximum rated output is limited to 800W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Table 42 UCS C220 M5 1050 W (AC) Power Supply Specifications
Table 44 UCS C220 M5 1600 W (AC) Power Supply Specifications
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (Vrms) 200 to 240
Maximum Allowable Input Voltage Range (Vrms) 180 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W) 1600
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) NA NA 8.8 7.9
Maximum Input at Nominal Input Voltage (W) NA NA 1778 1758
Maximum Input at Nominal Input Voltage (VA) NA NA 1833 1813
Minimum Rated Efficiency (%)
1
NA NA 90 91
Minimum Rated Power Factor
2
NA NA 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)
2
12
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
111
TECHNICAL SPECIFICATIONS
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
http://ucspowercalc.cisco.com
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
112
Environmental Specifications
The environmental specifications for the C220 M5 server are listed in Ta bl e 45.
Table 45 UCS C220 M5 SFF Environmental Specifications
Parameter Minimum
Operating Temperature Dry bulb temperature of 10°C to 35°C (50°F to 95°F)
Maximum temperature change of 20°C (36°F) per hour
(a temperature change within a spe
cified period of time and not
a rate of change)
Humidity condition: Uncontrolled, not to exceed 50% RH
starting
condition
Derate the maximum temperature by
1°C (33.8°F) per every 305
meters of altitude above 900m
Extended Operating Temperature 5°C to 40°C (41°F to 104°F) with no direct sunlight
Humidity condition: Uncontrolled, not to exceed 50% RH
starting
condition
Derate the maximum temperature by
1°C (33.8°F) per every 305
meters of altitude above 900m
Non-Operating Temperature Dry bulb temperature of -40°C to 65°C (-40°F to 149°F)
Operating Relative Humidity 10% to 90% and 28°C (82.4°F) maximum dew-p
oint temperature,
non-condensing environment
Minimum to be higher (more mois
ture) of -12°C (10.4°F) dew
point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90% relative humidity
Non-Operating Relative Humidity 5% to 93% relative humidity, non-condensing, with a m
aximum
wet bulb temperature of 28°C across the 20°C to 40°C dry bulb
range.
Maximum Operating Duration Unlimited
Operating Altitude A maximum elevation of 3050 meters (10,006 ft)
Non-Operating Altitude An elevation of 0 to 12,000 meters (39,370 ft)
Sound Power level, Measure
A-weighted per ISO7779 LWAd (Bels)
Operation at 23°
C (73°F)
5.5
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm (dBA)
Operation at 23°
C (73°F)
40
Tab l e 46 Cisco UCS C220 M5 Extended Operating Temperature Hardware Configuration Limits
Platform
1
Processors: 155W+ 155W+ and 105W+ (4 or 6 Cores)
Memory: LRDIMMs LRDIMMs
Storage: M.2 SATA SSDs
NVMe SSDs
M.2 SATA SSDs
NVMe SSDs
Peripherals: PCIe NVMe SSDs
GPUs
MRAID
PCIe NVMe SSDs
GPUs
mLOMs
VICs
NICs
HBAs
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
113
TECHNICAL SPECIFICATIONS
Extended Operating Temperature Hardware Configuration Limits
Notes:
1. Two PSUs are required and PSU failure is not supported
ASHRAE A3 (5
o
C to 40
o
C)
2
2. Non-Cisco UCS qualified peripherals and/or peripherals that consume more than 25W are not supported
ASHRAE A4 (5
o
C to 45
o
C)
3
3. High power or maximum power fan control policy must be applied
Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
114
Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in Tab l e 47.
Table 47 UCS C-Series Regulatory Compliance Requirements
Parameter Description
Regulatory Compliance Products should comply with CE Markings per d
irectives
2014/30/EU and 2014/35/EU
Safety UL 60950-1 Second Edition
CAN/CSA-C22.2 No. 60950-1 Second Edition
EN 60950-1 Second Edition
IEC 60950-1 Second Edition
AS/NZS 60950-1
GB4943 2001
EMC - Emissions 47CFR Part 15 (CFR 47) Class A
AS/NZS CISPR32 Class A
CISPR32 Class A
EN55032 Class A
ICES003 Class A
VCCI Class A
EN61000-3-2
EN61000-3-3
KN32 Class A
CNS13438 Class A
EMC - Immunity EN55024
CISPR24
EN300386
KN35